In these operating instructions, the designation “the tool” Always keep these operating instructions to- always refers to the PML 42 line laser. gether with the tool. Parts, operating controls and indicators 1 Ensure that the operating instructions are with the tool when it is given to other persons.
When the self-leveling range is exceeded, the laser beams blink to warn the user. The PML 42 is characterized by its ease of operation and use, its rugged plastic casing and ease of transport due to its compact dimensions and light weight.
Although the tool is protected to prevent entry c) To avoid the risk of injury, use only genuine Hilti of dampness, it should be wiped dry each time accessories and additional equipment.
Do not solder the batteries into the tool. under such conditions or if you are unsure. Likewise, Hilti g) Do not discharge the batteries by short circuiting cannot rule out the possibility of interference with other as this may cause them to overheat and present devices (e.g.
7 Operation Pivot the tool through 180° and mark the point of intersection of the laser lines on the opposite wall (B) with a cross. Place the tool on an even, level surface approx. 20 cm from the wall (B) with the laser beam directed NOTE toward the wall (B).
NOTE Do not use any other liquids as these may 8.4 Hilti calibration service damage the plastic components. We recommend that the tool is checked by the Hilti cal- Observe the temperature limits when storing your ibration service at regular intervals in order to verify its equipment.
Most of the materials from which Hilti tools or appliances are manufactured can be recycled. The materials must be correctly separated before they can be recycled. In many countries, Hilti has already made arrangements for taking back old tools or appliances for recycling.
We declare, on our sole responsibility, that this product Deutschland complies with the following directives and standards: 2004/108/EC, 2006/95/EC, 2011/65/EU, EN ISO 12100. Hilti Corporation, Feldkircherstrasse 100, FL‑9494 Schaan Paolo Luccini Matthias Gillner Head of BA Quality and Process Man-...
Need help?
Do you have a question about the PML 42 and is the answer not in the manual?
Questions and answers