Optical Parts Disassembly
, Locations and Directions
When mounting or assembling the optical parts in the opti-
cal unit, the parts must be mounted in the specified loca-
tion and direction as shown in figure below.
1
2
3
Point marker is
printed on this side
up
4
Point marker is
printed on this side
up
5
6
7
Marker comes this
side
8
528
--
No.
Parts Name
1
Integrator lens (OUT)
Prism beam splitter (PBS)
3
Condenser lens (OUT)
4
Dichroic mirror (B)
5
Dichroic mirror (G)
6
Condenser lens (G)
7
Relay Lens (IN)
8
Mirror (R)
9
Condenser lens (R)
10
Condenser lens (B)
11
Mirror (B)
Rugged surface
is facing this side.
Film attached
side is facing this
side.
Marker comes this
side
527
Marker comes this
side
11
10
9
8
Fig.8