Mechanical Disassembly
v Optical unit, Temp., Line Filter board, Fans and Speaker removal
1. Remove 5 screws A(T3x5) to remove the the Optical unit.
2. Remove 3 screws B (T3x8) and 4 hooks on the duct to remove
the Duct. top and bottom.
3. Remove screw C(T3x8) to remove the fan(FN904).
4. Remove 2 screws E(T3x6) and screw F(T3x6) to remove the Line filter
board and Temp. board.
5. Remove fans (FN905, FN907) and speaker (SP901).
C (T3x8)
A
B (T3x8)
Duct top
FN904
FN905
Hook
Hook
A(T3x8)x5
A
A
E (T3x6)x2
E
B
B
FN907
Hook
F (T3x6)
Hook
-15-
Optical unit
A
Line filter board
Noise filter
Temp. board
Duct bottom
SP901
Fig.4