Mechanical Disassembly
x Main Board, AV Board, Rear Panel and Fans removal
1. Remove screw A (M.5x6) to remove the Lamp top shield.
. Remove 4 screws B(M.5x6) to remove the Main board.
3. Release 4 hooks to remove the Rear panel and remove  screws
C(T3x6) to remove the Rear panel and AV board.
4. Remove  screws D(T3x6) to remove fans (FN901, FN90).
Main board
B (M.5x6)x4
AV board
Lamp top shield
c Fan (FN903) removal
1. Remove screw A(M3x8) to disconnect
the lamp ballast socket.
. Remove screw B(T3x8) to remove
fan (FN903).
C (T3x6)x
B
C
Hooks
B
A (M.5x6)
D
B (T3x8)
Trigger
A (M3x8)
Ballast
socket
Fig.3
-14-
Rear panel
B
D (T3x6)x
FN901
FN90
FN903
Trigger
* Trigger should be mounted as the
figure above.
Side grill
Fig.2
Duct