Electrical Adjustments
Group/
Item Name
Item
43 Lamp PWM PresPcA
44 Lamp PWM PresPcB
45 Lamp PWM PrefHAv50Hz
46 Lamp PWM PrefHAv60Hz
47 Lamp PWM PrefHUnlock
50 Lamp Replacement Display
51 Filter Warning Display
5 Lamp Counter reset Times
Factory Default Execute
54
Times
55 Motor Disable
56 Menu Position
57 Menu Position
58 Lamp Go Out
59 Souce Search Enable
60 Lanuage Default setting    0:English(Default) 1:Janpanese  
Group
option (signal)
201
0 FrameLock Option
 Field Sense Invert Enable
3
4 Sub Image Enable
6 Zoom Accelerator Enable
7 DZoom Reset by Keystone
8 Stability Count
9 Sensivity for Signal Lost
(HSYNC)
10 Sensivity for Signal Lost
(VSYNC)
11 Keystone Filter Center Value Reference Value
Group
option (McI model only)
202
0 Memory Viewer OSD
Group
lampcontorl
210
0 DIMMER_CTRL_LEVEL1
1
DIMMER_CTRL_LEVEL
 DIMMER_CTRL_LEVEL3
3 DIMMER_CTRL_LEVEL4
4 DIMMER_CTRL_LEVEL5
5 DIMMER_CTRL_LEVEL6
6 DIMMER_CTRL_LEVEL7
7 DIMMER_CTRL_LEVEL8
Function
Lamp Warning Display On / Off
Filter Warning Display On / Off
Reset Times of Lamp Counter
Reset times of Fanctory Default
Motors Disable
Move menu (X asis)
Move menu (Y asis)
Source Search Enable
Count Value of V-missing
Only used this value for No Signal
Judgement(Hz)
Only used this value for No Signal
Judgement(Line)
Memory Viewer OSD Display (1: Yes,
0: No)
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the
Value
Luminance Level  Data for Dimmer:
Dim Level  at the less than the
Value
Luminance Level 3 Data for Dimmer:
Dim Level 3 at the less than the
Value
Luminance Level 4 Data for Dimmer:
Dim Level 4 at the less than the
Value
Luminance Level 5 Data for Dimmer:
Dim Level 5 at the less than the
Value
Luminance Level 6 Data for Dimmer:
Dim Level 6 at the less than the
Value
Luminance Level 7 Data for Dimmer:
Dim Level 7 at the less than the
Value
Luminance Level 8 Data for Dimmer:
Dim Level 8 at the less than the
Value
Initial

3
5000
5000
5000
1
1
0
0
0
0
0
0
1
0
1
0
1
0
0
5
350
3
16
1
7
14
1
8
35
4
49
56
-41-
range Note
0-55
0-55
0-65535
0-65535
0-65535
0 - 1
1: On, 0: Off
0 - 1
1: On, 0: Off
0 - 55
Read only
0 - 55
Read only
0 - 1
0: On, 1: Off
0 - 104
0 - 104
0 - 1
0 - 1
0 - 1
Set the default language
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and
0 - 1
47Hz (Vfreq) ~ Panel frequency of
input signal
Reverse Processing of
FLDINVSetting Value
0: Disable - Used FLDINV Setting
0 - 1
Value
1: Enable - Used Reversed FLDINV
Setting Value
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
0 - 1
1:Enable (Service Adjustment
Enable)
0:Zoom Accelerator OFF,
0 - 1
1:Zoom Accelerator ON
No last memory
0:Enable (Normal), 1:Disable (Dzoo
is not cancelled even if Keystone is
0 - 1
cancelled)
No last memory
0 - 55
0 - 65535
0 - 55
0 - 30
0 - 1
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55