Download Print this page

Product Specifi Cation - Danfoss TP4000 Range Installation Manual

Electronic programmable room thermostat
Hide thumbs Also See for TP4000 Range:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Please Note:
This product should only be installed by a qualifi ed
electrician or competent heating installer and should
be in accordance with the current edition of the IEEE
wiring regulations.
GB
GB
1.0 Product Specifi cation
FR
Thermostat features
ES
Power supply
NL
Memory back-up
Switching action of
output relay
GR
Switch rating of relay
contact
PL
Transmission frequency
(RF Models)
CZ
Transmission range
Temperature range
TR
Dimensions, mm
Design standard
HR
Rated impulse voltage
Ball hardness test
RO
Control pollution
situation
Temperature accuracy
HU
Time accuracy
LT
Important note RF products: Ensure that there are no large metal
objects, such as boiler cases or other large appliances, in line of
sight between the transmitter and receiver as these will prevent
communication between thermostat and receiver.
4
TP4000
2 x AA/MN1500/LR
alkaline cells
1 min for battery change
1 x SPDT, Type 1B
3(1)A, 10-230Vac
Off , 5-30°C
110 wide, 88 high, 28 deep
EN60730-2-9
Degree 2
±1 min. per month
TP4000 RF
2 x AA/MN1500/LR
alkaline cells
N/A
N/A
433.92MHz
30m max
EN300220
2.5kV
75°C
±1°C
TP4000

Advertisement

loading

This manual is also suitable for:

Tp4000 rf