In the event of poor water quality it is recommended that a water
treatment professional be consulted for water treatment options. If the
magnesium anode is not properly serviced, the warranty expires on the
DHW tank.
Never bring the magnesium anode surface in contact
with oil or grease.
▶ Keep everything clean.
▶ Shut off the cold water inlet and DHW outlet.
▶ Depressurize the tank.
▶ Remove and check the magnesium anode.
Fig. 15
9.2
Startup after maintenance
▶ To start up the DHW tank, follow the steps in 6.1.
S 32/5 – 6 720 804 007 (2014/10)
1.
2.
6 720 801 708-12.1ITL
9
Maintenance
15