  • Page 1 Hydraulic pliers INSTRUCTION MANUAL Electro hydraulic crimping tool Art. 21 66 01 DIN EN ISO 9001 ZERTIFIKAT … convincing solutions...
  • Page 2: Technical Characteristics

    1. Technical characteristics Application field: A compression tool for crimping electrical connectors, suitable for copper conductors up to 400 mm and aluminium conductors up to 300 mm Force developed: 120 kN Press opening: 25 mm Rated operating pressure: 700 bar Oil type: ISO class viscosity 15 Voltage...
  • Page 3 Die holder Pushbutton for return movement Pushbutton to advance … convincing solutions Germany: HAUPA GmbH & Co. KG, Königstraße 165-169, D - 42853 Remscheid. Phone: +49 (0)2191 8418-0, Fax: +49 (0)2191 8418-840, sales@haupa.com • Errors and technical changes reserved.
  • Page 4: Battery Removal And Installation

    Start: - Place the tool in the operating position - Select the appropriate die for the connection to be made - Insert the die set in the tool head - Insert the conductor in the connector - Place the connector between the two dies. - Grip the tool and actuate the pushbutton to advance, the piston will rapidly advance until the dies are in contact with the connector to be crimped.
  • Page 5: Care And Maintenance

    Check that the machine switch is automatically released when you stop pressing it. Should you detect any anomaly, replace it immediately. … convincing solutions Germany: HAUPA GmbH & Co. KG, Königstraße 165-169, D - 42853 Remscheid. Phone: +49 (0)2191 8418-0, Fax: +49 (0)2191 8418-840, sales@haupa.com • Errors and technical changes reserved.
  • Page 6 Turn off the cap and fill in the oil on demand Reservoir oil level Ensure that the oil level is always above the black line on the viewer. Do not fill the reservoir with noncompatible oil or brake fluid. Oil type: VESTA HLP-15 manufactured by VERKOL or similar. Remove the reservoir cap and add oil to the level marked.
  • Page 7: Fault Diagnostics

    Loss of oil at the piston Broken o-rings Have specialised personnel replace the o-rings. … convincing solutions Germany: HAUPA GmbH & Co. KG, Königstraße 165-169, D - 42853 Remscheid. Phone: +49 (0)2191 8418-0, Fax: +49 (0)2191 8418-840, sales@haupa.com • Errors and technical changes reserved.
  • Page 8 1. Item code number 2. Item description 3. Instruction manual reference and/or date 4. Tool type 5. Tool serial number The guarantee will become void if spares other than the HAUPA original spares are used. Spare parts list Decription Decription Decription...
  • Page 9 Exploded assembly drawing Art. 21 66 01 … convincing solutions Germany: HAUPA GmbH & Co. KG, Königstraße 165-169, D - 42853 Remscheid. Phone: +49 (0)2191 8418-0, Fax: +49 (0)2191 8418-840, sales@haupa.com • Errors and technical changes reserved.