DSC-F717
19. Auto White Balance 3200K Check 2
Mode
Subject
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
Note 1: Perform this check after "Auto white Balance 3200K
Check 1" without a break.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
1
2
F
7C
3
F
7D
Processing after Completing Adjustment:
Order Page Address Data
1
RadarW
RadarW
RadarW
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Displayed data of page: F, address:
7C, 7D
Adjusting remote commander
00 to 2F, EE to FF
00 to 23, F6 to FF
Procedure
"Auto White Balance 3200K
Check 1" is completed.
Check that the data specified
value 1.
Check that the data specified
value 2.
Procedure
Perform "Auto White
Balance 3200K Check 3".
20. Auto White Balance 3200K Check 3
Mode
Subject
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
Note 1: Perform this check after "Auto white Balance 3200K
Check 2" without a break.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
1
2
F
82
3
F
83
Processing after Completing Adjustment:
Order Page Address Data
1
6
37
2
0
03
3
6-28
RadarW
RadarW
RadarW
RadarW
RadarW
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Displayed data of page: F, address:
82, 83
Adjusting remote commander
00 to 82, E7 to FF
00 to 6D, F1 to FF
Procedure
"Auto White Balance 3200K
Check 2" is completed.
Check that the data specified
value 1.
Check that the data specified
value 2.
Procedure
00
00
Release the data setting
performed at step 1 in "Auto
White Balance 3200K
Standard Data Input 1".
(Refer to page 6-22)