1. EVF Initial Data Input

Mode
Signal
Adjustment Page
Adjustment Address
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, and enter the data given in the following table.
Note: Press the PAUSE button each time the data are set, as the
data are written to non-volatile memory (EEPROM).
Address
Data
90
30
91
72
92
34
93
44
94
28
95
7F
96
08
97
80
98
94
99
82
9A
25
9B
1D
9C
2B
9D
00
A2
30
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
PLAY
Arbitrary
A
90 to 9D, A2
Remark
Fixed value
VCO Adjustment (NTSC mode)
VCO Adjustment (PAL mode)
Fixed value
Bright Adjustment
Fixed value
White Balance Adjustment
Contrast Adjustment
Fixed value

2. VCO Adjustment (PD-179 Board)

Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Menu setting:
1) VIDEO OUT of SET UP setting
......................... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't
set the menu setting to "PAL" )
Adjusting method:
Order Page Address Data
1
0
01
2
A
02
3
4
F1
4
4
1D
5
A
92
6
A
92
7
A
93
8
A
93
Processing after Completing Adjustments:
Order Page Address Data
1
A
02
2
4
F1
3
4
1D
4
0
01
6-44
PLAY
Arbitrary
Pin ws of CN305 on FR-194
board (EVF_VCO)
Frequency counter
A
92 (NTSC mode)
93 (PAL mode)
f = 15734 ± 100 Hz (NTSC mode)
f = 15625 ± 100 Hz (PAL mode)
Procedure
01
23
Press PAUSE button.
13
(NTSC mode)
82
(PAL mode)
Change the data and set the
frequency (f) to the NTSC
specified value.
Press PAUSE button.
Change the data and set the
frequency (f) to the PAL
specified value.
Press PAUSE button.
Procedure
00
Press PAUSE button.
00
(NTSC mode)
80
(PAL mode)
00

Advertisement

Table of Contents
loading

Table of Contents