Burner And Nozzle Specifications - Hotpoint Ariston PFS 640 MS /HA Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Burner and nozzle specifications

Table 1
Burner
Diameter
Fast (Large) (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
Supply
pressures
*
At 15°C and 1013 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
(1) Only for appliances with the security device.
A
R
S
PFS 640 MS /HA
EHP 640 /HA
Thermal Power
(mm)
kW (p.c.s.*)
Nom.
Red.
100
3.00
0.70
100
2.60
0.70
75
1.65
0.40
55
1.00
0.40
130
3.25
1.50
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
S
RR
PFS 640 MST /HA
EHP 640 T /HA
Liquid Gas
By-pass
Nozzle
1/100 (mm)
1/100
(1)
(mm)
41
39
86
41
39
80
30
28
64
30
28
50
60
61
91
28-30
A
TC
S
Naturale Gas
Flow*
Nozzle
Flow*
g/h
1/100
***
**
(mm)
218
214
116
286
189
186
110
248
120
118
96
157
73
71
71
236
232
133
309
37
20
20
25
17
35
45
25
GB
l/h
95
15