Exposure Time - JAI SP-5000M-CXP2 User Manual

Spark series 5m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

SP-5000M-CXP2 / SP-5000C-CXP2
Table37. The combination of Exposure Mode, Trigger Option and Trigger Mode
Exposure Mode
OFF
Timed
Trigger Width
Table 38. Associated GenICam register information
GenICam Name
Exposure Mode
Trigger Mode
Trigger Option
7.2.2

Exposure Time

This command is effective only when Exposure Mode is set to Timed. It is for setting exposure time.
The setting step for exposure time is 1 μsec per step.
Minimum:
Maximum:
Associated GenICam register
GenICam
Access
Name
Exposure
Mode
Exposure
Time
Exposure
Time
Raw
Trigger Option
N/A
OFF
RCT/
RCT continuous
PIV
N/A
Access
R/W
R/W
R/W
10 μsec
8 seconds
Values
Off
R/W
Timed
TriggerWidth
10
to
R/W
1000000 [us]
10
to
R/W
1000000 [us]
Trigger Mode
(Frame Start)
N/A
OFF
ON
Forced to ON
Forced to ON
Forced to ON
Values
Off
Timed
TriggerWidth
Off
On
Off
RCT
PIV
RCT Continuous
Category
Acquisition Control
Acquisition Control
Acquisition Control
- 35 -
Operation
Self-running operation
Exposure control by Exposure
Time is not possible
Self-running operation
Exposure control by Exposure
Time is not possible
Timed (EPS) Operation
Exposure can be controlled by
Exposure Time
RCT Operation
Exposure can be controlled by
Exposure Time
PIV Operation
Exposure can be controlled by
Exposure Time
Exposure is controlled by the
pulse width of the external trigger
Category
Acquisition Control
Acquisition Control
JAI-Custom

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-5000c-cxp2