Plumbing
– The inlet hose is approx. 1.5 m long.
A 1.5 m long flexible metal extension
hose, pressure tested to 14000 kPa/
140 bar) is available as an optional
accessory, if required.
– A stopcock with a 3/4" male thread
must be provided on site.
– This appliance is constructed to
comply with IEC/EN/DIN 61770 //
VDE 0700 Section 600, and may be
connected to a suitable supply with‐
out an extra non-return valve if na‐
tional regulations permit.
– The water pressure (flow pressure at
the take-off point) must be between
30 and 1000 kPa (0.3 und 10 bar). If
the water pressure is lower than this,
the fault message
appear in the display (see "Problem
solving guide"). If the water pressure
is too high, a pressure reducer valve
must be fitted.
82
will
Water intake
After connecting the dishwasher to
the water supply, check that all
plumbing connections are watertight.
To avoid any damage to the ap‐
pliance, the dishwasher must only be
operated when it is connected to a
fully vented plumbing system.
The inlet hose must not be
shortened or damaged in any way as
it contains electrical components
(see illustration).