Hotlogic Controller - Dux SunPro 2F136S Owner's Manual

Electric boosted solar water heater
Hide thumbs Also See for SunPro 2F136S:
Table of Contents

Advertisement

Hotlogic Controller

The Hotlogic controller should be
plugged in to a weatherproof approved
power outlet for 10amps, 230 to 250
volt, 50Hz supply.
Hotlogic Controller Diagnosis
Codes
The Hotlogic controller must be wired
according to the diagram shown right.
During normal operation, the Hotlogic
controller will display only green LEDs.
If there are any red status lights visible,
see the tables below for an explanation.
For models 2F136S, 3F136S,
4F136S:
Power
Status
LED
LED
(Green)
(Red)
Alternating
On
Off
On
On
Flashing
Off
Off
Flashing Tank bottom sensor error
Flashing
Flashing Tank top sensor error
Note: If any sensor is open circuit, the system will indicate a
Green only flashing LED.
H3161
025248
Owner's Manual – Dux Electric Boosted Solar
Hotlogic Controller
Explanation
Power on initialisation (LEDs blink alternately)
All sensors normal, pump off
All sensors normal, pump on or booster on
Sensor error (collector or tank)
Rev. D
Status
LED
Power
LED
19

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SunPro 2F136S and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF