  • Page 1 Operating and installatiOn instructiOns dHW Heat pumps » WWK 300 a » WWK 300 ap » WWK 300 aH » WWK 300 aHp...
  • Page 2: Table Of Contents

    1.3 Correct operation 1.4 Incorrect operation 1.5 Function description 1.6 Operation with active defrost feature WWK 300 A and WWK 300 AH 1.7 Operation with passive defrost feature WWK 300 AP and WWK 300 AHP 1.8 Maintenance and cleaning 1.9 Troubleshooting by the user...
  • Page 3: Operating Instructions For Users And Contractors

    Sand and dust can result in sludge active defrost feature 1.4 Incorrect operation building up inside the strainer. Therefore, WWK 300 A and WWK 300 AH clean the strainer at least twice per The following are not permitted: annum or in accordance with demand.
  • Page 4: Troubleshooting By The User

    Remove contaminants and blockages Other issues immediately. Safety valve of the cold water supply line For the WWK300 AH and WWK300 drips AHP, it is recommended that the This may occur during the heat-up phase electric booster heater be descaled and is completely normal.
  • Page 5: Installation Instructions For Contractors

    Installation instructions for contractors 2.1 Regulations and standards The following standards were taken into — Material of the cold water line: account: Steel, copper or plastic pipe installation (water and electrical systems. AS 4234, AS 3498, AS 4020, AS 1056.1 work) and commissioning, as well as —...
  • Page 6: Installation

    2.2 Installation — Flush the line prior to installation. The available floor area in the instal- lation room must be at least 6 m². Install a drain valve at the lowest point of Never install this equipment in rooms Transport the cold water supply line.
  • Page 7: Power Supply

    (only for the WWK 300 AH and AHP) 11 Solenoid valve V2 2 High limit safety cut-out (only for the WWK 300 A / AH) Electric booster heater 12 Solenoid valve V1 (only for the WWK 300 AH and AHP)
  • Page 8: Commissioning

    2.5 Commissioning or the control thermostat of the heat z Draining the cylinder: pump fails to respond. Reset the high — Close the shut-off valve in the cold Only approved contractors may pressure limit safety cut-out by pressing water supply. commission this equipment and instruct the reset button (pos 3, Fig.
  • Page 9 Abtaubetrieb WWK 300 E Kältekreis Schemata Operation with active defrost feature WWK 300 A and WWK 300 AH Heizbetrieb Heating operation Defrost operation >P >P Luft Valve - powered Valve - not powered = closed Ventil bestromt Ventil bestromt Valve - not powered = closed...
  • Page 10 Wiring diagram WWK 300 A F2 Compressor motor protection (Klixon) F3 High limit safety cut-out M1 Compressor M2 Fan N0 Heat pump control thermostat N2 Frost monitor V1 Solenoid valve V2 Solenoid valve X0 Power terminals X1 Heat pump terminals...
  • Page 11 Wiring diagram WWK 300 AP F2 Compressor motor protection (Klixon) F3 High limit safety cut-out M1 Compressor M2 Fan N0 Heat pump control thermostat N2 Frost monitor X0 Power terminals X1 Heat pump terminals X2 Anode terminal earth Z1 Capacitor Fig.
  • Page 12 Wiring diagram WWK 300 AH E1 Electric booster heater N1 Control thermostat, electric booster heater F1 High limit safety cut-out N2 Frost monitor Electric booster heater V1 Solenoid valve F2 Compressor motor protection (Klixon) V2 Solenoid valve F3 Safety pressure limiter X0 Power terminals Heat pump X1 Heat pump terminals...
  • Page 13 Wiring diagram WWK 300 AHP E1 Electric booster heater N0 Heat pump control thermostat F1 High limit safety cut-out N1 Control thermostat, electric booster heater Electric booster heater N2 Frost monitor F2 Compressor motor protection (Klixon) X0 Power terminals F3 Safety pressure limiter X1 Heat pump terminals Heat pump X2 Anode terminal earth...
  • Page 14: Specification

    2.7 Specification Type WWK 300 A WWK 300 AP WWK 300 AH WWK 300 AHP Part no. 222422 227069 227070 227071 Version with active defrost with passive defrost with active defrost with passive defrost and booster heater and booster heater Application limits for heat pump operation °C...
  • Page 15: Warranty

    A nominal service charge may be made should the appliance be found to be in normal working condition and the problem located elsewhere. Stiebel Eltron (Aust) Pty Ltd warrants the domestic range of heat pump to be in normal working condition and the problem located elsewhere.
  • Page 16 5 Tolich Place Henderson Auckland Tel: 09 836 6566, Fax: 09 836 6033 www.parex.co.nz Australia STIEBEL ELTRON Australia Pty.Ltd. Unit 4/109 Riverside Place, Morningside, QLD, 4170 Tel. 1800 153 351 Fax 07 3399 3344 Email info@stiebel.com.au www.stiebel.com.au ВозмоҖность неточностейи технических изменений...