Fluke 106 User Manual
Hide thumbs Also See for 106:

Advertisement

PN 4343876
June 2013
© 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one
year from the date of purchase. This warranty does not cover fuses, disposable
batteries, or damage from accident, neglect, misuse, alteration, contamination, or
abnormal conditions of operation or handling. Resellers are not authorized to
extend any other warranty on Fluke's behalf. To obtain service during the warranty
period, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow the exclusion or limitation of
an implied warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
11/99
106 & 107
Digital Multimeters
Users Manual
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 106

  • Page 1 Users Manual PN 4343876 June 2013 © 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase.
  • Page 2: Table Of Contents

    Measure AC or DC Current .................. 12 Measure Resistance ..................... 14 Test for Continuity ....................14 Test Diodes (107 Only) ..................16 106 & 107 Users Manual Measure Capacitance................... 17 Measure Frequency and Duty Cycle (107 Only) ..........17 Maintenance ......................18 General Maintenance ...................
  • Page 3: Introduction

    Unless otherwise identified, all illustrations show the 107. Safety Information The Fluke 106 and 107 comply with IEC 61010-1 CAT III 600 V overvoltage standard. See Specifications. A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that could cause damage to the Product or the equipment under test.
  • Page 4 • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc. • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage. 106 & 107 Users Manual • Keep fingers behind the finger guards on the probes.
  • Page 5 Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation" product. Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.
  • Page 6: Instrument Overview

    Input terminal for ac and dc current measurements to 10 A and current frequency (107 only) measurements. Common (return) terminal for all measurements. Input terminal for voltage, resistance, continuity, diode (107 only), capacitance, and frequency (107 only) measurements. 106 & 107 Users Manual Display hhc02.eps Item...
  • Page 7: Auto Power Off

    To disable both the Auto Power Off function and the Auto Backlight Off function, you can also hold down the Shift key and the key at the same time, until both PoFF and LoFF show on the display. 106 & 107 Users Manual Measurements Data Hold...
  • Page 8: Measure Ac Or Dc Current

    Volts AC Volts DC Millivolts AC hhc03.eps Figure 1. Measure AC and DC Voltage 106 & 107 Users Manual Measure AC or DC Current Warning To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product in the circuit when you measure current. Connect the Product in series with the circuit.
  • Page 9: Measure Resistance

    Users Manual Measure Resistance 1. Turn the rotary switch to (106 does not have the diode symbol). Make sure power is disconnected from the circuit to be measured. 2. Connect the red test lead to the terminal and the black test lead to the COM terminal.
  • Page 10: Test Diodes (107 Only)

    Multimeters Measurements < 70 hhc05.eps Figure 3. Measure Resistance/Continuity 106 & 107 Users Manual Test Diodes (107 Only) 1. Turn the rotary switch to 2. Push the YELLOW function button twice to activate Diode Test. 3. Connect the red test lead to the terminal and the black test lead to the COM terminal.
  • Page 11: Measure Capacitance

    3. To make a duty cycle measurement, push the button again. 4. Read the percent of duty cycle on the display. 106 & 107 Users Manual Maintenance Beyond replacing batteries and the fuse, do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service instructions.
  • Page 12: General Maintenance

    Users Manual Test the Fuse 1. Turn the rotary switch to (106 does not have the diode symbol). 2. Plug a test lead into the terminal and touch the probe to the A terminal. • A good A terminal fuse is indicated by a reading less than 0.1 Ω.
  • Page 13: Replace Batteries And The Fuse

    Product correctly. Replacement parts are listed below. Item Description Battery Battery door Test Lead Fuse To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) •...
  • Page 14: General Specifications

    Operating ..........2000 m Storage ............. 12,000 m Temperature Coefficient ......0.1 X (specified accuracy) /°C (<18 °C or >28 °C) Fuse protection for current inputs .... 11A, 1000V Fast Fuse, Fluke specified part only 106 & 107 Users Manual Size (HxWxL) ..........
  • Page 15: Accuracy Specifications

    [1] All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. [2] Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 106 & 107 Users Manual...
  • Page 16 DC Volts 600 V >10 MΩ <100 pF 50 Hz or 60 Hz 50 Hz or 60 Hz [1] 6 x 10 V Hz Max [2] For mV (AC), input impedance is approximately 1 MΩ. 106 & 107 Users Manual...

This manual is also suitable for:

107

Table of Contents