Fluke 101 User Manual

Fluke 101 User Manual

Digital multimeter

Advertisement

101
Digital Multimeter
Users Manual
July 2013, Rev. 2, 12/22
© 2013-2022 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 101

  • Page 1 Digital Multimeter Users Manual July 2013, Rev. 2, 12/22 © 2013-2022 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ......................... 1 Contact Fluke ......................1 Safety Information ...................... 2 Instrument Overview....................3 Terminals ........................ 3 Display ........................4 Rotary Switch ......................6 Auto Power Off ......................7 Measurements ......................8 Data Hold ....................... 8 Measure AC and DC Voltage .................
  • Page 4 Users Manual Measure Frequency and Duty Cycle ..............14 Maintenance ....................... 16 General Maintenance ..................... 16 Replace Batteries ....................17 Service and Parts ....................... 18 General Specifications ....................18 Accuracy Specifications ..................... 20...
  • Page 5: Introduction

    Introduction The Fluke 101 Multimeter (the Product) is a 6000-count instrument. The Product is battery powered with a digital display. Contact Fluke Fluke Corporation operates worldwide. For local contact information, go to our website: www.fluke.com To register your product, view, print, or download the latest manual or manual supplement, go to our website.
  • Page 6: Safety Information

    Users Manual Safety Information The Fluke 101 is rated to IEC 61010-1 CAT III 600 V measurement category. See General Specifications. A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that could cause damage to the Product or the equipment under test.
  • Page 7: Instrument Overview

    Digital Multimeter Instrument Overview Instrument Overview Terminals hkm01.tif Item Description Common (return) terminal for all measurements. Input terminal for all measurements.
  • Page 8: Display

    Users Manual Display Figure 1 and Table 1 show the items on the Product display. hkm02.tif Figure 1. Display...
  • Page 9 Digital Multimeter Instrument Overview Table 1. Display Item Description Item Description High voltage Frequency is selected Display Hold is enabled Farads Continuity selected Millivolts Diode test is selected Amps or volts Duty Cycle is selected Dc or ac voltage or current Decimal prefix Auto Range mode is enabled Ohms is selected...
  • Page 10: Rotary Switch

    Users Manual Rotary Switch hkm06.tif Figure 2. Rotary Switch...
  • Page 11: Auto Power Off

    Digital Multimeter Auto Power Off Table 2. Rotary Switch Functions Number Description Number Description Ohms. Push shift for continuity and Power down the Product. diode test. AC Volts Shift. Push for yellow functions. DC Volts Capacitance Freeze the display. Frequency. Push shift for duty cycle. AC millivolts Auto Power Off The Product automatically powers off after 20 minutes of inactivity.
  • Page 12: Measurements

    Users Manual Measurements Data Hold XW Warning To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured. To hold the present reading, push .
  • Page 13 Digital Multimeter Measurements hkm03.tif Figure 3. Measure AC and DC Voltage...
  • Page 14: Measure Resistance

    Users Manual Measure Resistance 1. Turn the rotary switch to . Make sure power is disconnected from the circuit to be measured. 2. Connect the red test lead to the J terminal and the black test lead to the COM terminal.
  • Page 15 Digital Multimeter Measurements hkm05.tif Figure 4. Measure Resistance/Continuity...
  • Page 16: Test Diodes

    Users Manual Test Diodes 1. Turn the rotary switch to 2. Push the YELLOW button twice to activate the diode test mode. 3. Connect the red test lead to the J terminal and the black test lead to the COM terminal.
  • Page 17 Digital Multimeter Measurements hkm08.tif Figure 5. Diode and Capacitance Tests...
  • Page 18: Measure Frequency And Duty Cycle

    Users Manual Measure Frequency and Duty Cycle To measure frequency: 1. Turn the rotary switch to I . 2. Connect the red test lead to the J terminal and the black test lead to COM terminal. 3. Measure frequency by touching the probes to the correct test points of the circuit. 4.
  • Page 19 Digital Multimeter Measurements hkm04.tif Figure 6. Measure Frequency/Duty Cycle...
  • Page 20: Maintenance

    Users Manual Maintenance Beyond replacing batteries, do not attempt to repair or service the Product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions. The recommended calibration cycle is 12 months. XW Warning To prevent possible electrical shock, fire, or personal injury: •...
  • Page 21: Replace Batteries

    Digital Multimeter Maintenance Replace Batteries hkm07.tif Figure 7. Replace Batteries...
  • Page 22: Service And Parts

    Users Manual Service and Parts If the Product fails, first check the batteries. Then, review this manual to make sure you are operating the Product correctly. Replacement parts are: Item Fluke Part Number Batteries 2838018 Battery door 4319659 Test leads TL175...
  • Page 23 Digital Multimeter General Specifications Altitude Operating ............2000 m Storage ............12,000 m Temperature Coefficient ........0.1 X (specified accuracy) / °C (<18 °C or >28 °C) Size (HxWxL) ............. 130 mm x 65 mm x 27 mm Weight ..............160 g IP Rating .............
  • Page 24: Accuracy Specifications

    Users Manual Accuracy Specifications Accuracy is specified for 1 year after calibration, at operating temperature range of 18 °C to 28 °C, relative humidity at 0 % to 90 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) Function Range Resolution...
  • Page 25 Digital Multimeter Accuracy Specifications Overload Input Impedance Common Mode Normal Mode Function Protection (Nominal) Rejection Ratio Rejection Ratio >60 dB at dc, AC Volts 600 V >10 MΩ <100 pF 50 Hz or 60 Hz >80 dB at dc, AC Millivolts 600 mV >1 M, <100 pF 50 Hz or 60 Hz...
  • Page 26 Users Manual Function Range Resolution Accuracy 400.0 Ω 0.1 Ω 0.5 % + 3 4.000 kΩ 0.001 kΩ 0.5 % + 2 Resistance 40.00 kΩ 0.01 kΩ 0.5 % + 2 400.0 kΩ 0.1 kΩ 0.5 % + 2 4.000 MΩ 0.001 MΩ...