Fluke 106 User Manual
Hide thumbs Also See for 106:

Advertisement

Find Quality Products Online at:
June 2013, Rev. 1, 10/15
© 2013-2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
GlobalTestSupply
www.
106/107
Digital Multimeters
Users Manual
.com
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 106

  • Page 1 106/107 Digital Multimeters Users Manual June 2013, Rev. 1, 10/15 © 2013-2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ....................... 1 How to Contact Fluke ....................1 Safety Information ....................2 Instrument Overview....................8 Terminals ......................8 Display ........................9 Auto Power Off ......................10 Auto Backlight Off ..................... 11 Measurements ......................11 Data Hold ......................
  • Page 4 106/107 Users Manual Measure Capacitance................... 19 Measure Frequency and Duty Cycle (107 Only) ..........19 Maintenance ......................20 General Maintenance ................... 21 Test the Fuse ......................22 Replace Batteries and the Fuse ................22 Service and Parts ..................... 24 General Specifications ....................25 Accuracy Specifications ....................
  • Page 5: Introduction

    Introduction The Fluke 106 and 107 Digital Multimeters (the Product) are 6000-count instruments. The Product is battery powered with a digital display. Except where noted, the descriptions and instructions in this Users Manual apply to both the 106 and 107.
  • Page 6: Safety Information

    106/107 Users Manual Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that could cause damage to the Product or the equipment under test. GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 7 Digital Multimeters Safety Information  Warning To prevent possible electrical shock, fire, or personal injury: • Carefully read all instructions. • Read all safety information before you use the Product. • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Page 8 106/107 Users Manual • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage. • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Page 9 Digital Multimeters Safety Information • Replace the batteries when the low battery indicator shows to prevent incorrect measurements. • Use only specified replacement parts. • Use only specified replacement fuses. • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Page 10 106/107 Users Manual Table 1 is a list of the symbols used on the Product and in this manual. Table 1. Symbols  Consult user documentation.  WARNING. RISK OF DANGER. Static awareness. Static discharge WARNING. HAZARDOUS VOLTAGE.  ...
  • Page 11 Digital Multimeters Safety Information Table 1. Symbols (cont.) Measurement Category II is applicable to test and measuring circuits connected directly to  utilization points (socket outlets and similar points) of the low-voltage MAINS installation. Measurement Category III is applicable to test and measuring circuits connected to the ...
  • Page 12: Instrument Overview

    106/107 Users Manual Instrument Overview Terminals hhc01.eps Item Description Input terminal for ac and dc current measurements to 10 A and current frequency (107 only)  measurements. Common (return) terminal for all measurements.  Input terminal for voltage, resistance, continuity, diode (107 only), capacitance, and ...
  • Page 13: Display

    Digital Multimeters Instrument Overview Display Figure 1 and Table 2 show the items on the Product display. hhc02.eps Figure 1. Display GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 14: Auto Power Off

    106/107 Users Manual Table 2. Display Item Description Item Description High voltage Frequency is selected    Display Hold is enabled  Farads Continuity selected Millivolts   Diode test is selected Amps or volts   Duty Cycle is selected Dc or ac voltage or current ...
  • Page 15: Auto Backlight Off

    Digital Multimeters Auto Backlight Off Auto Backlight Off The backlight automatically turns off after 2 minutes of inactivity. To disable the Auto Backlight Off function, hold down  when turning on the Product, until LoFF shows on the display. Note To disable both the Auto Power Off function and the Auto Backlight Off function, hold down the YELLOW button and ...
  • Page 16: Measure Ac And Dc Voltage

    106/107 Users Manual Measure AC and DC Voltage To measure ac and dc voltage: 1. Choose ac or dc by turning the rotary switch to   2. Connect the red test lead to the  terminal and the black test lead to the COM terminal.
  • Page 17 Digital Multimeters Measurements Volts AC Volts DC Millivolts AC hhc03.eps Figure 2. Measure AC and DC Voltage GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 18: Measure Ac Or Dc Current

    106/107 Users Manual Measure AC or DC Current  Warning To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product in the circuit when you measure current. Connect the Product in series with the circuit.
  • Page 19 Digital Multimeters Measurements hhc04.eps Figure 3. Measure AC and DC Current GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 20: Measure Resistance

     1. Turn the rotary switch to (106 does not have ). Make sure power is disconnected from the circuit to be measured. 2. Connect the red test lead to the  terminal and the black test lead to the COM terminal.
  • Page 21 Digital Multimeters Measurements < 70 hhc05.eps Figure 4. Measure Resistance/Continuity GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 22: Test Diodes (107 Only)

    106/107 Users Manual Test Diodes (107 Only)  1. Turn the rotary switch to 2. Push the YELLOW button twice to activate the diode test mode. 3. Connect the red test lead to the  terminal and the black test lead to the COM terminal.
  • Page 23: Measure Capacitance

    Digital Multimeters Measurements Measure Capacitance 1. Turn the rotary switch to . 2. Connect the red test lead to the  terminal and the black test lead to the COM terminal. 3. Touch the probes to the capacitor leads. 4. Let the reading stabilize (up to 18 seconds). 5.
  • Page 24: Maintenance

    106/107 Users Manual Maintenance Beyond replacing the batteries and fuse, do not attempt to repair or service the Product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions. The recommended calibration cycle is 12 months.
  • Page 25: General Maintenance

    Digital Multimeters Maintenance General Maintenance Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings. To clean the terminals: 1. Turn the Product off and remove the test leads. 2.
  • Page 26: Test The Fuse

    Test the Fuse  1. Turn the rotary switch to (106 does not have ). 2. Plug a test lead into the  terminal and touch the probe to the A terminal. • A good A terminal fuse is indicated by a reading less than 0.1 Ω.
  • Page 27 Digital Multimeters Service and Parts hhc07.eps Figure 5. Replace Batteries and the Fuse GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 28: Service And Parts

    Service and Parts If the Product fails, first check the batteries and fuse. Then, review this manual to make sure you are operating the Product correctly. Replacement parts are: Item Fluke Part Number Batteries 2838018 Battery door 4319659 Test leads TL175...
  • Page 29: General Specifications

    Digital Multimeters General Specifications General Specifications Maximum voltage between any terminal and Earth Ground ............600 V Fuse protection for A input ..........11 A, 1000 V, IR 17 kA Display (LCD) ..............6000 counts, updates 3/sec Battery Type ..............2 AAA, NEDA 24A, IEC LR03 Battery Life ..............
  • Page 30 106/107 Users Manual Temperature Coefficient ..........0.1 X (specified accuracy) / °C (<18 °C or >28 °C) Size (HxWxL) ..............142 mm x 69 mm x 28 mm Weight ................200 g IP Rating ................IEC 60529: IP 40 Safety General .................
  • Page 31 Digital Multimeters General Specifications Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. Korea (KCC) ..............
  • Page 32: Accuracy Specifications

    106/107 Users Manual Accuracy Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
  • Page 33 Digital Multimeters Accuracy Specifications Accuracy Function Range Resolution 400.0 Ω 0.1 Ω 0.5 % + 3 0.5 % + 3 4.000 kΩ 0.001 kΩ 0.5 % + 2 0.5 % + 2 Resistance 40.00 kΩ 0.01 kΩ 0.5 % + 2 0.5 % + 2 400.0 kΩ...
  • Page 34 106/107 Users Manual Accuracy Function Range Resolution 50.00 Hz 0.01 Hz Frequency 500.0 Hz 0.1 Hz 5.000 kHz 0.001 kHz 0.1 % + 3 50.00 kHz 0.01 kHz (10 Hz to 100 kHz) 100.0 kHz 0.1 kHz Duty Cycle 1 % to 99 % 0.1 %...
  • Page 35 Digital Multimeters Accuracy Specifications Accuracy Function Range Resolution AC Current 4.000 A 0.001 A (40 Hz to 200 Hz) 1.5 % + 3 1.5 % + 3 10.00 A 0.01 A  DC Current 4.000 A 0.001 A 1.5 % + 3 1.5 % + 3 ...
  • Page 36 106/107 Users Manual Overload Input Impedance Common Mode Normal Mode Function Protection (Nominal) Rejection Ratio Rejection Ratio >60 dB at dc, AC Volts 600 V >10 MΩ <100 pF 50 Hz or 60 Hz >80 dB at dc, AC Millivolts 600 mV >1 M, <100 pF...

This manual is also suitable for:

107107 esp95969678780

Table of Contents