Table of Contents Remote Control Instruction ------------------------------------------------------ 41~42 Package List --------------------------------------------------------------------- 01~02 Answering Alarm Phone Call to Start Remote Control ----------------------------- Control Panel Layout ------------------------------------------------------------ 03~04 Remote Control by Calling Fixed Phone Number----------------------------------- Preparation before Use --------------------------------------------------------- 05~06 Remote Control by Calling SIM Card Number ------------------------------------- Power on --------------------------------------------------------------------------...
Page 3
Features 100% wireless configuration, D.I.Y. installation Stylish design with touch keypad LCD with guide menu, easy for programming Built-in 1,000,000 RF codes combination maintains high reliability Support 10 remote controls, 50 wireless sensors, and 50 RFID tags Store 6 alarm phone numbers 10 seconds voice memo and alarm voice message recordable Disarm by RFID tags and unlock the electronic door lock Support maximum 150 alarm event logs...
As a PSTN/GSM dual networks alarm system, B11 panel will switch to GSM network automatically to call the user for alert when the PSTN network is cut off.
Control Panel Layout Rear Side Tamper Switch Speaker Front Side GSM Network LED Home Mode (Part Arm) RFID Tag Reader / Disarm Terminals for Play Voice Memo SIM Card Slot Wired Sensors AC Adapter Jack Landline Jack Power LCD Display ON/OFF Up/Down Backup Batteries...
Insert the SIM card only after the control panel is switched off. Then, switch on the control B11 is a PSTN & GSM dual networks alarm system, If there is an alarm, it will auto dial panel so as to search signals.
Control Panel Operation Disarm Input user code (Default: 1234) or admin code (Default: 123456) first, Alarm Control then press the [Disarm button, Arm (Away Arm) the system enters disarm state when Press the [Arm button on the one beep is heard and the disarm control panel, the system enters Arm LED Indicator lights on.
Access Control System Voice Memo Press the [Record Voice Memo button for 3 seconds to record 10 seconds voice The control panel has a RFID reader for message. The Play Voice Memo circle will be flashing to remind you. Users can touch unlocking the electronic door lock by disarming the center of circle to listen to the voice memo.
Security Alarm Function Press the [Arm button, the system enters arm state when one beep is heard and the arm LED on the control panel is on. Test Accessories Our accessories can work only with our control panels, can not work with other brands. Note: If Exit Delay is activated, all zones except the 24-hour zone will enter arm state after the...
Mute Operation Door/Window Contact When arm or disarm the system, the siren will The door/window contact can be installed on doors, windows, and any other objects that can open and close. The sensor transmits signals to the control panel when a magnet beep accordingly.
Test Pet-Immune PIR Motion Detector 1. Press the back cover and slide down to remove the back cover. The detector adopts digital dual-core fuzzy logic control processing technology and 2. Remove the insulating strip. The contact works immediately. intelligent analysis algorithm, effective resolution of interfering signal and human 3.
Page 12
Test Working Mode Testing mode 1. Remove the insulating strip 2. Arm Press the buckle to open the back Press the [Arm button on the After self-testing, the detector enters testing mode, and detects once cover. Remove the insulating strip. remote control.
Page 13
Installation 3. Testing Press the test button on the back of the detector, walk in the detection scope and watch 1. Choose installation place the LED indication to make sure the detector is working. It is recommended to mount it at the height of 2m from the ground. (For installation notices, please see page 21-22) 4.
Page 14
3. Avoid facing to glass windows or doors Installation Notices Pay attention to the following during installation: Strong light interferes with detection sensitivity. In addition, complicated 1. Mount the detector to a location close to the entry or exit situations, such as traffic flow, stream of The detector aims at preventing intrusion.
LCD Display Contents Disarm Arm or Disarm Home Arm System Status Display content Alarm Line Disconnect AC Power Failure Alarm Host Low Battery Linecut GPRS Connected Alarm Stand-by Sensor 1-50(Sensor Name) Panel Tamper Alarm Low Battery Alarm NO SIM CARD Wired Sensor GPRS Connecting Sensor1-50(SensorName)
LCD Display Menu Date Date And Date Format Time When LCD is activated, input the admin code (Default: 123456), and then press [Enter] Time to enter setting menu. Entry Delay <000S> Entry Exit Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3 Delay Exit Delay <000S>...
Settings Ringing Times Alarm Message Record When LCD is activated, input the admin code (Default: 123456), and then press [Enter] to enter setting menu. Siren On/Off <On/Off> Wired Siren Important: The default language of this alarm system is English, you can change in the Arm/Disarm Tone <On/Off>...
2. Add/Delete/Edit Accessories Delete If user wants to delete the added RFID cards or tags, please choose “Delete” in step The control panel only receives signal from accessories after they are connected to the as above and press [Enter] . Then choose to delete all or specific RFID cards or tags, control panel.
Date Format Normal Sensor: In arm mode, when normal sensors are triggered, system will alarm. In disarm mode, when normal sensors are triggered, system will not alarm. Log on the menu, press , choose “System Settings”, press [Enter] 24 Hour Sensor: Under any circumstances, when 24 hour sensors are triggered, system Press , choose “Date and Time”, press...
Page 20
Exit Delay Timed Disarm Exit delay is set to leave time for user to exit before the system is armed. Log on the menu, press , choose “System Settings”, press [Enter] Log on the menu, press , choose “System Settings”, press [Enter] confirmation.
Page 21
Access Code Ringing Times for Remote Phone Control After the set ringing times, user can make system settings from remote calling, such as All the alarm panels are with default user code, admin code and duress code. Please arming/disarming the system. change all codes before using and keep your codes secret.
Page 22
Turn On/Off Arm/Disarm Beep for Wired Siren Built-in Siren Built-in siren is the siren inside the control panel. Log on the menu, press , choose “System Settings”, press [Enter] Press , choose “Siren Setup”, press [Enter] Turn On/Off Built-in Siren Press , choose “Wired Siren”, press [Enter]...
Connect to CMS User ID for CMS Please see details at Page 40: Connect to CMS Please ignore this step if users don't need to connect to CMS center. Upload Arm Report When connected to CMS center, control panel will upload contact ID to CMS center Please see details at Page 41: Connect to CMS automatically once intrusion is detected.
Upload Arm/ Disarm Report to CMS Center Remote Control by Calling Telephone Number When this function is enabled, all arm/disarm reports will be uploaded automatically to Call the telephone number of alarm system. After getting through, input user code or CMS center, so that CMS center can know the status of the alarm system.
SMS Operation Home Mode (Part Arm) In home mode, detectors setting to home mode zone are in disarmed status; the other detectors are still in armed status. That is, you can move freely in the home mode zone; You can control the system by sending SMS commands to the SIM card No. SMS is however, the rest areas are still being protected.
Adding accounts enables you to bind the alarm systems to your smart phone. You can Download and Install APP add more accounts to control several B11 alarm systems on one phone. Search keywords “B11 alarm” in Apple Store or Google Play, downloads it for free. ① Enter [Accounts]...
Some SIM cards need to set APN to open GPRS function. If the GPRS function of the SIM card in B11 doesn’t work out. Do as follow: Send 'APN' to the SIM card in the control panel; you’ll get a message back. Forward and fill in related APN, username and password,, then send it back.
Page 28
Registering account enables you to bind the alarm systems to your smart phone. Login to enter the main menu, user can perform disarm, arm, home arm, monitor and leave voice memo. ① Enter login interface Tap B11 APP , choose [GPRS] , and then the login interface appears. 13211110000 ****** 3.
4. Refresh Maintenance Press to refresh the current system state. The alarm system features unique and brilliant design and craftwork. Please use it with caution. The following suggestions will help prolong the service life of the system. 1 Keep this product and accessories out of children's reach. 2 Keep the product and accessories dry.
Specifications CG-B11 Control Panel Phenomena Cause of Malfunction Troubleshoot Method Open battery compartment, Power Supply Input DC 12V 500mA, 6Wh Power switch is off turn on the power Standby Current < 90mA No response from Contact local main power control panel...
DWC-102 Wireless Door/Window Contact Disclaimer Power Supply DC 1.5V (AA 1.5V LR6 Battery x 1 pc) Static Current < 35uA Dear users: Alarm Current < 10mA We have reviewed this manual thoroughly in order that it will be an easy to use guide Transmitting Distance <...
Need help?
Do you have a question about the B11 and is the answer not in the manual?
Questions and answers