A11
Security Alarm System
Printed in China
PA: A11-UM-EN-V1.0
2014 Chuango. All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Chuango CG-A11

  • Page 1 Security Alarm System Printed in China PA: A11-UM-EN-V1.0 2014 Chuango. All rights reserved.
  • Page 2 Features PSTN/LCD/RFID 100% wireless configuration, D.I.Y. installation Touch Alarm System Fashion design with digital touch keypad LCD display with guide menu, easy for programming ARM + Auror high quality CPU Built-in 1, 000, 000 RF codes combination maintains high reliability Support 10 remote controls, 50 wireless sensors and 50 RFID tags Store 6 alarm phone numbers and 2 ADEMCO CID CMS numbers 10 seconds voice memo and alarm voice message recordable...
  • Page 3: Table Of Contents

    Table of Contents Included Accessories Keypad Tones Control Panel Layout Access Code Ringing Times for Phone Remote Control Preparation before Use Alarm Message Siren Setup Power on User ID for CMS Connect PSTN Land Line Upload Arm Report Installation Upload Disarm Report Reset Check Event Logs Control Panel Operation...
  • Page 4: Included Accessories

    Included Accessories CG-A11 Control Panel x1 The control panel is known as the “heart and brain” for alarm system, which is used for receiving and processing signals from wireless sensors and remote controls. Users can make settings freely with the keypad and LCD display.
  • Page 5: Control Panel Layout

    Control Panel Layout Rear Side Buzzer Tamper Switch Front Side Speaker RFID Tag Reader / Play Voice Memo Home Mode (Part Arm) Disarm LCD Display Power ON/OFF PSTN Land Line Interface AC Adapter Interface Interfaces for Wired Sensors Up/Down Backup Batteries Enter Output Wired Siren ≤...
  • Page 6: Preparation Before Use

    Preparation before Use 1. Power on 2. Connect PSTN Land Line A11 is a PSTN alarm system which will auto dial the pre-stored phone Plug the output connector of AC adapter into the adapter interface of number when the system detects intruders. Please make sure the panel control panel.
  • Page 7: Control Panel Operation

    Control Panel Operation 1. Alarm Control Arm (Away Arm) Disarm Press the [Arm button on the control panel, the system enters Arm Input user code or admin code first, then press the [Disarm button, state when one beep is heard and the Arm LED Indicator lights on. the system enters Disarm state when one beep is heard and the Disarm LED Indicator lights on.
  • Page 8: Access Control System

    LCD Display Contents 2. Access Control System The control panel has a RFID reader for unlocking the electronic door lock by disarming the system. Just place the RFID tag close to the RFID reader, System Status Display content the green LED indicator flashes once. Line Disconnect The system is disarmed and the electronic door lock is open (If connected) Stand-by...
  • Page 9: Lcd Display Menu

    LCD Display Menu Date When LCD is activated, input the admin code, and then press [Enter] Date And Time enter setting menu. Date Format Time Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3 Entry Delay <000S> Entry Exit Delay Exit Delay <000S>...
  • Page 10: Settings

    Settings Siren On/Off <On/Off> Wired Siren Arm/Disarm Tone <On/Off> When LCD is activated, input the admin code, and then press [Enter] enter setting menu. Siren On/Off <On/Off> Wireless Siren Arm/Disarm Tone <On/Off> Siren Setup Siren On/Off <On/Off> 1. Alarm Phone Number Setup Built-in Siren Arm/Disarm Tone <On/Off>...
  • Page 11: Add/Delete/Edit Accessories

    2. Add/Delete/Edit Accessories Delete The control panel only receives signal from accessories after they are If user wants to delete the added RFID cards or tags, please choose connected to the control panel. “Delete” in the step as above and press [Enter] .
  • Page 12: System Settings

    3. System Settings 3.1 Date and Time Normal Sensor: In armed mode, when normal sensors are triggered, alarm system will alarm. In disarmed mode, when normal sensors are Date triggered, alarm system will not alarm. Log on the menu, press , choose “System Settings”, press [Enter] 24 Hour Sensor:...
  • Page 13: Backlight Time

    Entry Delay 3.4 Timed Arm / Disarm Entry delay is set to leave time for user to disarm the system before the User can set timed arm and disarm according to daily schedule to avoid sensors send signal to control panel after triggering after the set time. repeated operation.
  • Page 14: Remote Phone Control

    3.6 Remote Phone Control Remote Phone Control Instruction Table Users can set to turn on/off remote phone control to get free access to Phone Explanation Function the alarm system for arming, disarming and on site monitoring by dialing Buttons telephone no. of the system Arm the system Phone voice prompt “Arm Succeed”...
  • Page 15: Access Code

    3.9 Access Code Duress Code All the alarm panels are with default user code, admin code and duress In case of emergency, when user is violently requested to disarm the code. Please change all codes before using and keep your codes secret. system, it's recommended to use the duress code to disarm the alarm system.
  • Page 16: Siren Setup

    3.12 Siren Setup Wireless Siren Wireless siren is connected to control panel through wireless connection. Users can turn on/off wired siren, wireless siren, built-in siren as well as arm/disarm beep, and set siren ringing time. Turn on/off wireless siren Wired Siren Log on the menu, press , choose “System Settings”, press [Enter]...
  • Page 17: User Id For Cms

    3.16 Reset Turn On/Off Arm/Disarm Beep for Built-in Siren Log on the menu, press , choose “System Settings”, press [Enter] Log on the menu, press , choose “System Settings”, press [Enter] Press , choose “Siren Setup”, press [Enter] Press , choose “Reset”, press [Enter] to reset the system to Press...
  • Page 18: Connect To Electronic Lock

    Connect to Electronic Lock Delete CMS Phone Number Log on the menu, choose “Phone Numbers”, press [Enter] Please ignore this if user is not intended to put this alarm as access control. Press , choose “Del Phone Number ”, press [Enter] This alarm only sends on/off signal to electronic door lock, please refer to Press...
  • Page 19: Precautions

    Precautions To prevent harm to users or other people during usage of the product and Phenomena Cause of Malfunction Troubleshoot Method to extend the lifespan of the product, please follow the precautions below: Open battery compartment, Power switch is off turn on the power No response from General Instruction...
  • Page 20: Specifications

    Wireless Remote Control Specifications Product Name LED Indicator PSTN/LCD/RFID Touch Alarm System Model No. CG-A11 Disarm Stay Power Supply Input: DC 12V 500mA, 6Wh Panic Standby Current ≤ 90mA Alarm Current ≤ 300mA Backup Battery 2 Cells of 3.7V 800mAh Li-ion Battery(BL-5B)
  • Page 21: Emergency Call

    Disarm Mute Mode Press the [Disarm button on the remote control, the system enters When arm or disarm the system, the control panel will beep once or twice. Disarm state when two beeps are heard and the Arm LED Indicator goes out. If siren beep is not needed, operation as follows: Press and hold the [Stay...
  • Page 22: Wireless Door/Window Contact

    Wireless Door/Window Contact LED Indication LED flashes once: Door/window is opened and transmitter sends signal to Features the control panel. Flash once per 3 seconds: Low power indication, please change battery as The DWC-102 is a Door/Window Contact that can be installed on doors, soon as possible.
  • Page 23 Installation & Notice Specifications Power supply Remove the battery activation strip, the sensor will enter working state DC 1.5V (AA 1.5V LR6 Battery x 1pc) immediately. Mount the sensor on the door frame and the magnet on the door. Static current Make sure the magnet is on the right side of the transmitter ≤...
  • Page 24: Pet-Immune Pir Motion Detector

    Pet-Immune PIR Motion Detector LED Indication Display Meaning Features Blink continuously Self testing PIR-910 is a high performance wireless P.I.R. motion detector. It consists of Blink once Intrusion detected digital dual-core fuzzy logic infrared control chip and intelligent analysis Testing mode is finished, the detector which effectively identify interference signals from body movement signals Blink twice enters power-saving mode...
  • Page 25 WorkingMode Power saving mode Testing mode The product features power-saving design. If the detector detects human After self-testing, the detector enters testing mode, and detects once every movement twice in 3 minutes, it will switch to the sleeping state to save 10 seconds.
  • Page 26 Installation Test the PIR motion detector Press the test button at the back. It switches to the testing mode and sustains Choose a suitable installation location for 3 minutes. Walk in the detection scope and observe the LED. When body movement is detected, the LED blinks once.
  • Page 27 Installation Notices Don't face to glass windows or doors Mount the detector to a location close to the entry or exit Strong light interferes with detection The detector aims at preventing intrusion. Detecting human movement at sensitivity. In addition, complicated the entry or exit is critical for security.
  • Page 28 Specifications Power Supply DC 3V (AA 1.2V LR6 Battery x 2 pcs) Static Current ≤ 90uA Alarm Current ≤ 9.5mA Detection Scope 8m/110° Pet Immunity ≤ 25kg Transmitting Distance ≤ 80m (in open area) Radio Frequency 433.92MHz (± 75KHz) Housing Material ABS plastic Operation Condition Temperature: -10°C~+55°C...