Technical Data - Napoleon LE485RB Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

Gas Hose
If the hose and regulator are not included by the manufacturer, then only hoses and regulators which
meet national and regional codes are to be used.
Ensure that the hose does not come into contact with grease, other hot drippings, or any hot surfaces
on the appliance.
Check hose regularly. In the case of rips, melting or wear, replace hose before using the appliance.
The recommended hose length is 0.5m. The hose must not be longer than 1.5m.
Ensure that the hose is twist and kink free when installed.
Replace the hose before expiry date printed on the hose.

Technical Data

The following table lists input values for the appliance.
Burner
Orifice Size
I
Main
1.18mm (56)
1.65mm
Back
1.04mm (59)
1.51mm (53)
Side
1.02mm (60)
1.45 mm
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
I
I
3B/P(30)
3+(28-30/37)
Orifice Sizes
I
I
(see above)
Gases / Pres-
Butane 30mbar
Butane 28-30mbar
sures
Propane 30mbar
Propane 37mbar
Countries
BE, BG, CY, DK,
BE, CH, CY, CZ, ES,
EE, FI, FR, GB,
FR, GB, GR, IE, IT,
HR, HU, IS, IT, LT,
LT, LU, LV, PT, SK, SI
LU, MT, NL, NO,
RO, SE, SI, SK, TR
Do not tamper with or modify regulator. Use only regulator which supply the pressure listed in the table
above. A regulator of 28 – 30 mbar must be used for butane or a 37 mbar regulator for propane. The grill
is equipped with an internal regulator. This internal regulator has an outlet pressure of 24.5 mbar for propane/
butane and 18.5 mbar for natural gas and must not be modified or adjusted. For replacement, use only
the regulator specified by the manufacturer.
This unit includes an internal regulator which stabilizes the gas pressure and improves grill performance.
This regulator cannot be adjusted. There is a pressure tap located on the side of the regulator. It can
be used by a qualified service person when servicing the grill to determine if the regulator is functioning
properly. The screw within the pressure tap must always be kept tight, except when performing a pressure
test on the regulator (qualified service personnel only).
(Gross) Heat Input (Total)
II
14.4 kW
4.0 kW
3.8 kW
I
I
3B/P(37)
3B/P(50)
I
I
Butane 37mbar
Butane 50mbar
Propane 37mbar
Propane 50mbar
PL
AT, CH, DE, SK
Gas Usage (Total)
I
II
1042 g/hr
1370 L/hr
290 g/hr
380 L/hr
275 g/hr
362 L/hr
I
I
2H(20)
2E(20)
II
II
Natural Gas
Natural Gas 20mbar
20mbar
AT, BG, CH, CZ, DK,
DE, LU, PL
EE, ES, FI, GB, GR,
HR, HU, IE, IS, IT,
LV, LT, NO, PT, RO,
SE, SI, SK, TR
www.napoleongrills.com
5
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Le485Le485rsibLe485sbLe485sibLe485rsb

Table of Contents