Z85230 (ESCC™), which is suitable for the most popular communication protocols including HDLC/SDLC, X.25, Bi-Sync, Mono-Sync, and asynchronous. The ACB-232.LPCI is compliant with EIA/TIA-232E. What’s Included The ACB-232.LPCI is shipped with the following items. If any of these items are missing or damaged, contact the supplier. • ACB-232.LPCI Adapter •...
Technical Description Technical Description The ACB-232.LPCI utilizes the Zilog 85230 Enhanced Serial Communications Controller (ESCC). This chip features programmable baud rate, data format and interrupt control. Refer to the ESCC Users Manual for details on programming the 85230 ESCC chip.
Technical Note: Please terminate any control signals that are not going to be used. The most common way to do this is connect RTS to CTS and RI. Also, connect DCD to DTR and DSR. Terminating these pins, if not used, will help insure you get the best performance from your adapter. Sealevel Systems ACB-MP.PCI Page 3...
2. Make sure the Sealevel Systems adapter is securely installed in a PCI slot. 3. Use the supplied software and User Manual to verify that the Sealevel Systems adapter is configured correctly. 4. Windows users can use the installed programs in the SeaMAC folder to verify operation.
2. When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics. 3. Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.htm...
(usually +3 to +10 volts) represents a binary 0 (space) and -12 volts (-3 to -10 volts) denotes a binary 1 (mark). The RS-232 and the EIA/TIA-574 specification defines two type of interface circuits, Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The Sealevel Systems adapter is a DTE interface. Sealevel Systems ACB-MP.PCI...
Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives. Sealevel Systems ACB-MP.PCI Page 9...
Sealevel Systems assumes no liability for any damages, lost profits, lost savings or any other incidental or consequential damage resulting from the use, misuse of, or inability to use this product. Sealevel Systems will not be liable for any claim made by any other related party.