ACB-MP.LPCI
User Manual | 5102
1
© Sealevel Systems, Inc.
5102 Manual | SL9240 7/2021

Advertisement

Table of Contents
loading

Summary of Contents for SeaLevel ACB-MP.LPCI

  • Page 1 ACB-MP.LPCI User Manual | 5102 © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 2: Table Of Contents

    APPENDIX B – HOW TO GET ASSISTANCE ..................... 17 APPENDIX C – ELECTRICAL INTERFACE ......................18 APPENDIX D – SILK SCREEN – 5102 PCB ....................... 20 APPENDIX E – COMPLIANCE NOTICES ......................21 WARRANTY ................................ 22 © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 3: Before You Get Started

    Before You Get Started What’s Included The ACB-MP+4.PCIe is shipped with the following items. If any of these items is missing or damaged please contact Sealevel for replacement. • ACB-MP+4.PCIe Adapter (Item# 5402e) • 100-Pin to (4) DB25M Breakout Cable, 36” in Length (Item# CA339)
  • Page 4: Introduction

    ‘All in One’ desktop computers. A standard height bracket is available for implementations in a standard height PCI slot. The ACB-MP.LPCI is a ‘Universal Bus’ adapter, allowing for use in either +5V or +3.3V PCI slots and provides compliance with the PCISIG PCI Bus Specification Revision 2.2/2.3, which requires ATX power support for both 5V and 3.3V.
  • Page 5 Optional Items Depending upon your application, you are likely to find one or more of the following items useful for interfacing the ACB-MP.LPCI to real-world signals. All items can be purchased from our website (http://www.sealevel.com) or by calling 864-843-4343. DB25 Female to DB25 Male Extension Cable, 72 inch Length (Item# CA104) The CA104 is a standard DB25F to DB25M serial extension cable.
  • Page 6: Installation & Configuration

    Only users running Windows 7 or newer should utilize these instructions for accessing and installing the appropriate driver via Sealevel’s website. If you are utilizing an operating system prior to Windows 7, please contact Sealevel by calling 864.843.4343 or emailing support@sealevel.com...
  • Page 7: Physical Installation

    5. Replace the screw (required for FCC Part 15 compliance). 6. Replace the cover. 7. Connect the power cord and power up the machine. 8. The ACB-MP.LPCI is now ready for use. © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 8: Technical Description

    Technical Description The ACB-MP.LPCI utilizes the Zilog 85230 Enhanced Serial Communications Controller (ESCC). This chip features programmable baud rate, data format and interrupt control. Refer to the ESCC User Manual, available from Zilog, for details on programming the Z85230 ESCC chip in the event you are writing your own driver as opposed to using the SeaMAC driver.
  • Page 9 Interface Selection The ACB-MP.LPCI supports a variety of electrical interfaces. Refer to the Control and Status Register Definitions found in the Technical Description section of this manual for this bit description. There is line termination on RXD, RXC, and TXC in the following modes: RS-530, RS-530A, RS-485T, and V.35.
  • Page 10 Local Loopback Output Data Terminal Ready Output Remote Loopback Output TSET Transmit Signal Element Timing Output Test Mode Input In External Sync Mode, the external sync signal is fed into CTS. © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 11 The RX+/- lines do not have pull up or pull down biasing. For high baud rates or long distances, add 1K Ω resistor from RX- to GND, and add 820 Ω resistor from RX+ to +5V DTR (depending on state of DTR in application – do not toggle DTR). © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 12 Data Set Ready Positive Input DTRB DTR+ Data Terminal Ready Positive Output TSETA TSET– Transmit Signal Element Timing - Output In External Sync Mode, the external sync signal is fed into CTS. © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 13 Output DTRA DTR– Data Terminal Ready Negative Output Remote Loopback Output TSETA TSET– Transmit Signal Element Timing - Output In External Sync Mode, the external sync signal is fed into CTS. © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 14 TSETA TSET– Transmit Signal Element Timing - Output All modem control signals are single ended (un-balanced) with RS-232 signal levels. In External Sync mode, the external syn signal is fed into CTS. © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 15: Technical Specifications

    2.54 inches (6.45 cm) Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100% electrically tested. These printed circuit boards are solder mask over bare copper with either Electroless Nickel Immersion Gold (ENIG) or Hot Air Solder Leveled (HASL) finish.
  • Page 16: Appendix A - Troubleshooting

    No two adapters can occupy the same I/O address. 6. Try the Sealevel Systems adapter with a unique IRQ. While the Sealevel Systems adapter does allow the sharing of IRQs, many other adapters (i.e., SCSI adapters and on-board serial ports) do not.
  • Page 17: Appendix B - How To Get Assistance

    When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics. Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
  • Page 18: Appendix C - Electrical Interface

    0 (space) and -12 volts (-3 to -10 volts) denotes a binary 1 (mark). The RS-232 and the EIA/TIA-574 specification defines two type of interface circuits, Data Terminal Equipment (DTE) and Data Circuit- Terminating Equipment (DCE). The Sealevel Systems adapter is a DTE interface. RS-422 The RS-422 specification defines the electrical characteristics of balanced voltage digital interface circuits.
  • Page 19 In RS-530 the signals all of the modem control signals are differential, in RS-530A some of these signals are single ended. The RS 530 specification defines two types of interface circuits, Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The Sealevel Systems adapter is a DTE interface.
  • Page 20: Appendix D - Silk Screen - 5102 Pcb

    Appendix D – Silk Screen – 5102 PCB © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 21: Appendix E - Compliance Notices

    Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives. © Sealevel Systems, Inc. 5102 Manual | SL9240 7/2021...
  • Page 22: Warranty

    Sealevel's commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn-in and testing.