Media Calibration - Argox G Series User Manual

Industrial barcode printer
Table of Contents

Advertisement

Media Calibration

After the first time of installation, the printer media is changed or
the media sensor board is replaced, the media sensor calibration
must be performed.
1. Load the media (and ribbon for thermal transfer printing)
properly.
2. Shift the media sensor to proper position.
3. Press and hold PAUSE/CALIBR. button then turn on the
power switch.
4. When "CALIBRATION..." is displayed on the LCD, release
the FEED button.
During media calibration, a few inches of media will be fed out.
The READY and MEDIA indicators will blink for few seconds
during calibration is proceeding. Without the proper
calibration, the gap detection will not stable especially for the
small label (less than 2.0 inches in height).
After the calibration, all the related parameters will be stored in
the EEPROM of main board.
Note:
After the first time of installing the media or the media type is
changed, this procedure must be carried out. Failing to do it, the
media-empty and media-gap detection might be incorrect.