Advertisement

AS-8000 SERIES
MANUAL
ARGOX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AS-8000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Argox AS-8000 Series

  • Page 1 AS-8000 SERIES MANUAL ARGOX...
  • Page 2 NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation.
  • Page 3 Using the ArgoxScan 8000/8110/8120/8150/8250/8310/8312 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid direct reflections that impair the reading performance, especially for 2D barcode.
  • Page 4: Table Of Contents

    Table of Contents Introduction ..........1 Default setting ......... 2 ArgoScan 8000 / 8120 ......4 ArgoScan 8150 / 8250 / 8310 / 8312 ..7 Programming the ArgoScan ....10 Parameter Setting ........12 Interface Selection ........ 12 Keyboard wedge ........13 RS-232 ..........
  • Page 5 Code-93 ..........70 Code-11 ..........73 MSI/plessey .......... 75 UK/plessey ..........77 Telepen ..........78 Standard 2 of 5 ........81 China Post ..........83 Italian Pharmacode (Code 32) ....85 Code-16K (for 8250/8312) ....87 PDF-417 (for 8250/8312) ..... 89 EAN UCC Composite (for 8312) ..
  • Page 6 Test Chart ..........111 ASCII Code Table ........ 115 Parameter Setting List ......117...
  • Page 7: Introduction

    Introduction Installation- Keyboard Wedge First of all, you must switch off power for the terminal/computer. Disconnect the keyboard cable from the back of the terminal/computer. Connect the appropriate interface cable to the scanner and to the terminal/computer. Turn the terminal/computer power on. RS-232 Disconnect power to the terminal/computer.
  • Page 8: Default Setting

    Default setting For each barcode shown as below: Read Checksum Checksum Code Enable Code Type Verification Transmission Enable Enable 8000 / 8120 UPC-A UPC-E EAN-13 EAN-8 * Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 V two digits...
  • Page 9 Read Enable Checksum Checksum Code Code Type Verification Transmission 8250 Enable Enable 8150 8310 8312 UPC-A UPC-E EAN-13 EAN-8 * Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 V two digits Code-93 & V One digit Code-11 MSI/Plessey...
  • Page 10: Argoscan 8000 / 8120

    ArgoScan 8000 / 8120 Specification Model 8000 Model 8120 Operational Light Source 660 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0-150 mm 0-150 mm (CODE 39, (code 39, PCS=90%, 20mils) PCS=90%, 20mils) Scanning Width 75mm at contact 75mm at contact...
  • Page 11 Cable – K/B wedge, Straight 2.0 m RS-232, USB Connector type RJ-45 phone jack connector Case material Cushion material Rubber Electrical Input Voltage 5 VDC ± 0.25V Power - Operating 250 mA 1250mW Power - Standby 30 mA 300 mW Current - Operating 250mA @ 5 VDC 250mA@5 VDC...
  • Page 12 Programming Programming Manual (Reading special barcode) DOS method command through RS-232, Program upgrade Enabled built-in flash memory (8110) Code type selection, check digit Programmable selection Decoding option Decoding characteristics option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type (intermessage delay, keyboard type...
  • Page 13: Argoscan 8150 / 8250 / 8310 / 8312

    ArgoScan 8150 / 8250 / 8310 / 8312 Specification Model Model 8150/8250 8310/8312 Operational Light Source 660 nm Visible Red 630 nm Visible Red Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0-250 mm Up to 600mm (CODE 39, (CODE 39, PCS=90%, 20mils)
  • Page 14 Width-handle 26 mm 30 mm Width-head 74 mm 78 mm Depth-handle 51 mm 56 mm Depth-head 35 mm 35 mm Weight 150 g (cable not 176 g (cable not included) included) Cable – K/B wedge Straight 2.0 m Coiled 2.5 m Cable –...
  • Page 15 Operating 0℃ to 45℃ 0℃ to 45℃ Temperature (32℉ to 113℉) (32℉ to 113℉) Storage -40℃ to 60℃ -20℃ to 60℃ (-40℉ to 140℉) (-4℉ to 140℉) Humidity 5% to 90% relative humidity, non-condensing Light Level Up to 60000 (8150); Up to 70000 Lux.
  • Page 16: Programming The Argoscan

    Programming the ArgoScan 8000/8110/8120/8150/8250/8310/8312 To program the 8110/8120/8150/8250/8310/8312, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.
  • Page 17 Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge 00* Interface RS-232 selection Wand emulation Keyboard/RS-232 Exit Option Barcode Back Fold Out Exit Barcode Finish barcode...
  • Page 18: Parameter Setting

    Parameter Setting Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface.
  • Page 19: Keyboard Wedge

    Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer.
  • Page 20 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard”...
  • Page 21 * Belgium Keyboard layout Danish France Germany Italian Portuguese Spanish Swedish Switzerland Latin American Japanese 00-08 0 : high clock rate (8150/8250) Keyboard speed 8 : low clock rate (83XX/8120) Disable * Enable Function key * Alphabetic key Numeric keypad Numeric key (Num lock state only)
  • Page 22 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on.
  • Page 23 Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” * Caps lock”OFF” Caps lock * Disable Enable Power-on simulation 00-99 msec 00-99 * Inter-character delay 00-99 10 msec 00-99 * Block transmission delay Exit...
  • Page 24: Rs-232

    RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 11 Xoff: Transmit Off (ASCII Code13 Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol.
  • Page 25 Program Option Bar Code Option Alphanumeric Entry None * RTS/CTS Flow control Xon/Xoff ACK/NAK 00-99 (msec) 00-99 * Inter-character delay 00-99 (10 msec) 00-99 * Block transmission delay 00-99 (100 msec) 00-99 * Response delay Exit...
  • Page 26 Program Option Bar Code Option Alphanumeric Entry 300 BPS 600 BPS Baud rate 1200 BPS 2400 BPS 4800 BPS 9600 BPS * 19200 BPS 38400 BPS None * Parity Even 8 bits * 7 bits Data bit One bit * Two bits Stop bit Exit...
  • Page 27: Wand Emulation

    Wand Emulation (for 8110/8150/8250) Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high- Black will be transmitted as a low voltage level (0V) and space as high level (+5). Initial polarity: You must make sure what is Initial polarity of your wand decode device in stand-by (idle).
  • Page 28 Wand Emulation (for 8110/8150/8250) Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar. Margin delay: It is a timer of zone like space zone of barcode label margin.
  • Page 29 Program Option Bar Code Option Alphanumeric Entry 620 pps 1250 pps Output speed 2500 pps * 5000 pps 10000 pps 20000 pps *pps: pixel per second * Reserved * Reserved 00-99 (10 pixel) 00-99 * Margin delay 00-99 (10 msec) 00-99 *...
  • Page 30: Pin Assignments

    Pin Assignments AS Series 8-pin RJ-45 Connector RS-232 Keyboard VCC (+5V) VCC (+5V) CLK / PC DATA / PC DATA / KB CLK / KB 8-pin 10-pin AS Series 10-pin RJ-45 Connector RS-232 Keyboard VCC (+5V) VCC (+5V) CLK / PC DATA / PC DATA / KB CLK / KB...
  • Page 31 Keyboard Wedge Combo Connector (To Host Side): Mini-DIN 6P Male DIN 5P Female DATA / PC DATA / KB VCC (+5V) VCC (+5V) CLK / PC CLK / KB DIN 5P Female Connector Mini-DIN 6P Male Connector RS-232 DB-9F Connector (To Host Side): Definition VCC (+5V)
  • Page 32 Keyboard Wedge PS/2 Connector (To Host Side): Mini-DIN 6P Male Mini-DIN 6P Female DATA / PC DATA / KB VCC (+5V) VCC (+5V) CLK / PC CLK / KB Mini-DIN 6P Female Connector Mini-DIN 6P Male Connector...
  • Page 33: System Control

    System Control Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning.
  • Page 34 Program Option Bar Code Option Alphanumeric Entry Good-read off * Momentary Scanning mode Alternate Timeout off Continue Test only 01-99 (second) 00-99 * Stand-by duration 01-99 (10 msec) 01-99 * Double read timeout 00-99 00-09 * (00: no double Double confirm confirm) 00-64 00-64...
  • Page 35 Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code length or more than max. code length will not be read. In popular, you can set the same value for both min.
  • Page 36 Program Option Bar Code Option Alphanumeric Entry 00-99 00-99 (00-64) (AS-8120) * Global min. code length 00-99 04-99 * (00-64) Global max. code length (AS-8120 , * * Disable Enable Inverted image scan * Disable Enable CTS trigger * Disable Enable Power saving mode (For 8310/8312)
  • Page 37 Scan Position indication (8110 excluded): If the function is enabled, scan beam will flash as a pointer to help you aim at the bar code prior to scanning. The code will not be scanned until you press the trigger. Stand mode selection: Normally activated with continuous mode.
  • Page 38 Program Option Bar Code Option Alphanumeric Entry * Disable 30 second Position indication 60 second 90 second 120 second 150 second 180 second Continue * LED ‘’on’’ LED ‘’off’’ Stand mode selection * Disable Enable *7AM* PCS Enhancement *7AL (For 8120) Exit...
  • Page 39: Indication

    Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq.
  • Page 40 Program Option Bar Code Option Alphanumeric Entry Disable * Enable Power on alert Disable * Enable LED indication Disable * Enable Beeper indication 00-07 00-07 * Beep loudness 00-99 (100Hz) 00-99 * Beep tone freq. 00-99 (10 msec) 00-99 * Beep tone duration Exit...
  • Page 41: Code Option

    Code Option UPCA Format Leading Data Digits Check Zero (11 Digits) Digit Read: Enable or disable the read function. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero.
  • Page 42 Program Option Bar Code Option Alphanumeric Entry Disable * Enable Read Disable * Enable Check-sum transmission 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < A > Code ID setting Exit...
  • Page 43 UPCA Insertion group number selection: The scanner offers max. two insertion groups for one symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. The function is to insert specific characters as a group into transmitted data of selected symbologies.
  • Page 44 Program Option Bar Code Option Alphanumeric Entry 00-44 00-44 * Insert group number selection * None 2 digits Supplement digits 5 digits (For 8110/8150/8250) UCC/EAN 128 Auto detection None 00* 2 digits Supplement digits 5 digits (For 8120/8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128...
  • Page 45 UPCA Truncation / Expansion: The leading “0” digits of UPCA data characters can be truncated when the function is enabled.
  • Page 46 Program Option Bar Code Option Alphanumeric Entry Disable * Enable Truncation/ Expansion (For 8110) None * Truncate leading Truncation/ zero Expansion (For Expand to EAN13 8120/8150/8250/ 8310/8312) Exit...
  • Page 47: Upce

    UPCE Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Program Option Bar Code Option Alphanumeric...
  • Page 48 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < E > Code ID setting Exit...
  • Page 49 UPCE Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Supplement digits: Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (6 Digits) Digit UCC/EAN Expansion: The expansion function is used only for UPCE and EAN-8 code reading.
  • Page 50: Ean-13

    * None 2 digits Supplement digits 5 digits (For 8120/8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 * Disable Enable Truncation/Expansion (For 8110) * None Truncate leading Truncation/Expansion zero (For 8120/8150/8250/ Expand to EAN13 8310/8312) Expand to UPCA *...
  • Page 51 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate leading zero: Refer to Truncation / Expansion of UPCA. Program Option Bar Code Option Alphanumeric Entry...
  • Page 52 0-15 00-15 * Truncate ending Disable * Enable Truncation leading zero Exit...
  • Page 53 EAN-13 Code ID setting: Refer to page 36 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (12 Digits) Digits UCC / EAN ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two...
  • Page 54 * None 2 digits Supplement digits 5 digits (For 8110/8150/8250) UCC/EAN 128 Auto detection * None 2 digits Supplement digits 5 digits (For 8120/8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 5, UCC/EAN * Disable Enable ISBN/ISSN conversion Exit...
  • Page 55: Ean-8

    EAN-8 Read: Format Data Digits Check (7 Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
  • Page 56 0-15 00-15 * Truncate ending Two characters 00-ffH, 00-ffH * 00-ffH ASCII < FF > Code ID setting code 00-44 00-44 * Insert group number selection Exit...
  • Page 57 EAN-8 Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (7 Digits) Digits UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Program Option Bar Code Option Alphanumeric Entry *...
  • Page 58 * Disable Enable Truncation / Expansion (For 8110) * None Truncate leading Truncation / zero Expansion Expand to EAN13 (For 8120/8150/8250 /8310/8312) * Disable Enable Expansion Exit...
  • Page 59 Code 39 Read: Format Start Data Digits Checksum “★” ( Variable) (Optional) “★” Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted.
  • Page 60 * Disable Enable Check-sum verification * Disable Enable Check-sum transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-20 00-20 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < > Code ID setting Exit...
  • Page 61: Code 39

    Code 39 Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
  • Page 62 * Standard Full ASCII Format * Disable Enable Append * Disable Enable Start/end transmission Exit...
  • Page 63: Interleaved 2 Of 5

    Interleaved 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 64 * Disable Enable Check-sum transmission 00-64 00-64 * Max. code leading 00-64 00-64 * Min. code leading 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < i > Code ID setting 00-44 00-44 *...
  • Page 65: Industrial 2 Of 5

    Industrial 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
  • Page 66 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < i > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 67: Matrix 2 Of 5 Eur

    Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 68 * Disable Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < B > Code ID setting 00-44 00- 44 *...
  • Page 69: Codabar

    Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 70 * Disable Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < % > Code ID setting Exit...
  • Page 71 Codabar Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
  • Page 72: Code-128/Gs1-128

    Code-128 /GS1-128 Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry Disable *...
  • Page 73 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character.
  • Page 74 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < # > Code ID setting 00-44 00-44 * Insert group number selection Standard UCC/EAN-128 Format Default AS-8000/8120 Default AS-8150/8250/8310 /8312 Exit...
  • Page 75: Code-93

    Code-128 Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format.
  • Page 76 Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry...
  • Page 77 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Program Option Bar Code Option...
  • Page 78 00-ffH ASCII 00-ffH * code < & > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 79: Code-11

    Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min.
  • Page 80 * Disable Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < O > Code ID setting 00-44 00-44 *...
  • Page 81: Msi/Plessey

    MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 82 Mod 11/10 * Disable Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < @ > Code ID setting 00-44 00-44 *...
  • Page 83: Uk/Plessey

    UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 84 * Disable Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < @ > Code ID setting 00-44 00-44 *...
  • Page 85: Telepen

    Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 86 Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < S > Code ID setting 00-44 00-44 * Insert group number selection Numeric only *...
  • Page 87: Standard 2 Of 5

    Standard 2 of 5 Read: Format Data Digits Checksum1 (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 88 * Disable Enable Check-sum transmission 00-64 00-64 * Max. code length *JAC 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < i > Code ID setting 00-44 00-44 *...
  • Page 89: China Post

    China Post Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
  • Page 90 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < t > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 91: Italian Pharmacode (Code 32)

    Italian Pharmacode (Code 32) Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
  • Page 92 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 01-ffH * code < p > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable Leading “A” Exit...
  • Page 93: Code-16K (For 8250/8312)

    Code-16K (for 8250/8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry *...
  • Page 94 00-44 00-44 * Insert group number selection Exit...
  • Page 95: For 8250/8312)

    PDF-417 (for 8250/8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
  • Page 96 Program Option Bar Code Option Alphanumeric Entry Disable * Enable Read 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable Escape sequence transmit...
  • Page 97: Ean Ucc Composite (For 8312)

    EAN UCC Composite (for 8312) For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the right of the UPC/EAN in UCC/EAN-128 symbology. Program Option Bar Code Option Alphanumeric Entry * Disable Enable Read 00-64 00-64...
  • Page 98 00-ffH 00-ffH * ASCII code < RC > Code ID setting 00-44 00-44 * Insert group number selection *YAH Disable * Enable UCC / EAN128 *YAI emulation Exit *YAK...
  • Page 99: Rss-14

    RSS-14 Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission, Code ID transmission must be set as AIM ID enable.
  • Page 100 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < R4 > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable UCC/EAN128 emulation Exit...
  • Page 101: Rss-Limited

    RSS-Limited Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 102 00-ffH ASCII 00-ffH * code < RL > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable UCC/EAN128 emulation Exit...
  • Page 103: Rss-Expanded

    RSS-Expanded Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
  • Page 104 00-99 00-99 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < RX > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable UCC/EAN128 emulation Exit...
  • Page 105: Micro-Pdf (For 8312)

    Micro-PDF (for 8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry *...
  • Page 106 00-44 00-44 * Insert group number selection None GLI protocol * Escape sequence ECI protocol *XAI transmit Exit *XAJ...
  • Page 107: String Format

    String Format String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Code Barcode...
  • Page 108 Program Option Bar Code Option Alphanumeric Entry * None 1-22 characters 00-ffH ASCII Prefix characters code setting * None 1-22 characters 00-ffH ASCII Suffix characters code setting Exit...
  • Page 109: String Setting/Transmission (Preamble/Postamble)

    String setting/Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted.
  • Page 110 Program Option Bar Code Option Alphanumeric Entry * None 1-22 characters 00-ffH ASCII Preamble characters code setting * Disable Enable Preamble transmission * None 1-22 characters 00-ffH ASCII Postamble code characters setting * Disable Enable Postamble transmission Exit...
  • Page 111: String Setting / Transmission (Insert Group Characters)

    String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The scanner supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data.
  • Page 112: String Setting / Transmission (Insert Group Characters)

    5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. Insert data group 1-4 position. Please refer to Chapter- Transmission, page 65 and in specific barcode that you want to use. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol.
  • Page 113 String setting / Transmission (Insert Group Characters) Program * None 1-22 characters 00-ffH ASCII Insert G3 characters code setting * None 1-22 characters 00-ffH ASCII Insert G4 characters code setting 00-63 00-63 * (00: no insertion) Insert data group 1 position 00-63 00-63...
  • Page 114 position 00-63 00-63 * (00: no insertion) Insert data group 4 position Exit...
  • Page 115: String Setting / Transmission (Others)

    String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected.
  • Page 116 * Before code data After code data Code ID position * Disable Proprietary ID Code ID AIM ID transmission * Disable Enable Code length transmission * Disable Enable Code name transmission * Disable Upper case Case conversion Lower case *For barcode data only Exit...
  • Page 117: Appendix

    Appendix Test Chart (Bar code samples marked with symbol “*” are enabled initially.) CODABAR-PARA (8110 *) CODE-11 PARA CODE-128 PARA * CODE-39 PARA * CODE-93 PARA EAN-13 PARA *...
  • Page 118 PDF-417 (8250/8312 *) STANDRAD-25 PARA CODE-16K 87549 EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA *...
  • Page 119 INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA...
  • Page 120 Micro-PDF (8312 *)
  • Page 121: Ascii Code Table

    ASCII Code Table Note: For keyboard wedge only. Null Down Left Right PgUp PgDn Home Enter Insert Ctrl+ Delete Alt+...
  • Page 122 “ & ‘ ★ ﹛ , < \ ︱ ﹜ > 〜...
  • Page 123 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110/8120/8150/8250/8310/8312, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code. Unique parameter list If you wish to display the unique parameter setting list, scan the unique parameter list bar code System parameter setting list If you wish to display the product information and revision...
  • Page 124 format list, scan the String setting list bar code. Query present scanner firmware version Program Firmware version list If you wish to display the firmware version, scan the “Firmware version list” barcode. Exit Reset scanner to factory default settings Program WARNING: Default value initialization If you wish to return the AS-8110/8120/8150/8250/8310 to all the factory default settings, scan the Default value...
  • Page 125 Finish...