Transportation; Storage - Hyundai HCP652 User Manual

Gasoline-powered waterpump
Table of Contents

Advertisement

INTENSIVE CLEANING
1. Remove / unscrew all 6 pump casing bolts from the pump.
2. Carefully remove the outside casing, exposing the impeller.
3. Clean impeller using regular soap and water, if necessary use a light
scrubbing tool to remove debris.
4. Reinstall casing on trash pump and fasten all bolts.
When reinstalling the casing, ensure that the rubber seal is properly secure all
around the perimeter of the opening.

5.9 - Transportation

Engine and exhaust can become hot. Avoid contact due to risk of burns and
fires. Allow engine to cool before transporting unit.
Do not drop or strike the pump during transport. Avoid placing heavy objects
on the frame or gas tank.
• Make sure engine and fuel valve are in the OFF positions
• Keep the unit level to prevent spillage.
• Place pump on a solid, level surface and secure it to prevent movement
during transport

5.10 - Storage

Do not store close to sources of heat, flames or sparks
Do not store in extremely humid or dusty areas
Do not store with gasoline still inside carburator or gas tank
1. Clean the impeller and drain water out
2. Drain gasoline from tank and carburator
3. Change engine oil