Commissioning Procedure; Warranty - Kemlan Horizon 3 Sided Installation Instructions Manual

Table of Contents

Advertisement

Installation Instructions Kemlan Natural Draft Electronic Ignition 3 Sided Gas Fireplaces

Commissioning Procedure

Installed correctly the burner should not emit any fumes
into the room. The following procedure should be
undertaken to test that the unit is operating correctly.
1. After unit has been operating for a short period a
smoke match, smoke tube, carbon dioxide analyser
or similar should be directed at the top opening of the
unit.
2. This procedure should be undertaken with the
following conditions in the room:
Open or closed windows
Operation of extraction/exhaust fans, range hoods etc
Operation of other gas appliances
Operation of optional appliance fan at any speed.
3. Should any spillage be detected the cause must be
rectified before allowing commissioning of unit.
User Instructions
1. WARNING NOTE: Properly installed and operated
this appliance will not leak gases. Persistent fume
emission must not be tolerated. If fume emission does
exist, then the following immediate action should be
taken. A Open doors and windows to ventilate room.
Turn the fire off.
Check for flue blockage and clear if necessary.
Do not attempt to relight the burner until the cause of
the emission has been identified and rectified. Should
assistance be required contact nearest agent.
The gas burner is designed to work in a Kemlan
Horizon electronic power flue ignition system. Working
correctly there will be no spillage. Unit should cut out if
not enough draw to ensure proper functioning.
2. Initially the Kemlan coal fire may burn with a slightly
blue flame. After approximately 20 minutes the fire
will settle down and burn with a yellow flame.
3. As with all gas fires your gas coal/pebble or log fire
should be regularly serviced. We recommend once
each year. Service information for an authorised
person to follow has been set out in attached leaflet.
4. PLEASE NOTE: Only logs provided by Kemlan
should be used with this appliance.
5. DO NOT place articles on or against this appliance.
DO NOT use or store flammable materials near this
appliance.
DO NOT spray aerosols in the vicinity of this appliance
whilst it is in operation. Primarily a decorative
appliance not certified as a space heater.
6. The appliance is a live fuel effect product designed to
operate with luminous flames and may exhibit slight
carbon deposition.
7. The guard is fitted to this appliance to reduce the risk
of fire or injury from burns and no part of it should be
permanently removed.
SERVICE - WARNING: ONLY TO BE SERVICED
BY AN AUTHORISED PERSON

Warranty

Provided the appliance has been correctly installed
according to instructions, Kemlan guarantee the cost of
replacing parts and the labour in connection therewith for
a period of 12 months from the date of installation.