Technical Data
Minimum - Maximum Water Pressure
Minimum - Maximum Water Temperature
Liquid Line Thermistor Resistance (Ohms) at 32°F (0°C) / 77°F (25°C)
Bin Thermostat Cut In / Cut Out
Total Unit Amperage
Refrigerant Charge (134a)
#7012423 - Revision A - August, 2009
Model UC-15I (Undercounter Ice Machine)
Technical Data
7-2
20 - 80 psi (1.4 - 5.5 bar)
35 - 90°F (1.6 - 32.2°C)
30K-33K / 8K-12K
40°F(4.5°C) / 34°F(1.0°C)
4.1
5.6 oz. (1.5 kg)