Power tool
Speed in 2nd gear
Speed in 3rd gear
Torque with tool set to drilling
symbol (soft/flexible joint)
Torque (driving screw in hard
en
material) set to drilling symbol
Torque range (15 settings)
Hammering speed
Hammer drilling in brick and
masonry (max. length 80 mm)
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a
standardised test given in EN 60745 and may be used to compare one tool with another. It may be used for a
preliminary assessment of exposure. The declared vibration emission level represents the main applications of
the tool. However if the tool is used for different applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly increase the exposure level over the total working
period. An estimation of the level of exposure to vibration should also take into account the times when the
tool is switched off or when it is running but not actually doing the job. This may significantly reduce the
exposure level over the total working period. Identify additional safety measures to protect the operator from
the effects of vibration such as: maintain the tool and the accessories, keep the hands warm, organisation of
work patterns.
Noise and vibration information (measured in accordance with EN 60745):
Typical A-weighted sound power level for the
SF 151-A
Typical A-weighted sound power level for the
SFH 151-A
Typical A-weighted emission sound pressure level
for the SF 151-A
Typical A-weighted emission sound pressure level
for the SFH 151-A.
Additional information in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
Screwdriving without impact action, a
Uncertainty (K)
Additional information in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
Hammer drilling in concrete, a
Drilling in metal, a
Uncertainty (K) for triaxial vibration measurements
Battery
Rated voltage
Capacity
18
Printed: 07.07.2013 | Doc-Nr: PUB / 5070659 / 000 / 00
SF 151-A
0...1,455/min
Max. 33 Nm
Max. 70 Nm
2...12 Nm
h
h,ID
h,D
SFB 150
15.6 V
2 Ah
SFH 151-A
0...1,380/min
0...2,000/min
Max. 33 Nm
Max. 70 Nm
2...12 Nm
36,000/min
1.5...6 mm
88 dB (A)
104 dB (A)
77 dB (A)
93 dB (A)
measured in accordance with EN 60745 2 2
< 2.5 m/s
1.5 m/s
measured in accordance with EN 60745 2 1
11.8 m/s
< 2.5 m/s
1.5 m/s
SFB 155
15.6 V
3 Ah