Type NR.
: LM201W01 (LG.PHILIPS)
Outside dimensions
: 459.4(H) x 296.4 (V) x 22.8(D) mm (Typ.)
Pixel Pitch ( mm )
: 0.258mm x 0.258mm
Color pixel arrangement : RGB vertical stripes
Display surface
: Hard coating(3H) & Anti-glare (Haze 25%)
treatment of the front polarizer
Color depth
: 16.7M colors (8 bits)
Backlight
: Six CCFL's
Active area(WxH)
: 433.44x270.9mm (20.1"W diagonal)
View angle
: Horizontal & Vertical 178 degree (CR>=10,TYP)
Contrast ratio
: 800:1(TYP)
White luminance
: 300 cd/m2 (Center 1 point, Typ.)
Scanning frequencies
Horizontal scan
: 30 - 83 KHz
Vertical scan
: 56 - 76 Hz
Video dot rate
: < 165 MHz
: 90-264 V AC, 50/60 ± 2 Hz
Power input
Power consumption
: <60W maximum, <50W ( typ.)
Power Management Definition:
Mode
HSYNC VSYNC
Video
Power-On
On
On
active
Off
Off
Off
blanked
DC Power Off
N/A
Pin Assignment
Pin No.
Assignment
Red video input
1
2
Green video input
3
Blue video input
4
GND
Cable detect
5
Red video GND
6
Green video GND
7
8
Blue video GND
Input DVI-D connector pin

Technical Data

Pwr-cons.
Indication
Rec. time
< 50 W(W/O USB)
Green LED
--
<60W(W/USB)
< 2 W
Amber LED
< 3 s
< 1 W
LED Off
Pin No.
Assignment
9
DDC +3.3V OR +5V
10
GND
11
GND
12
Serial data line (SDA)
H-sync
13
V-sync
14
15
Data clock line (SCL)
Pin No.
1
T.M.D.S. data2-
2
T.M.D.S. data2+
3
T.M.D.S. data2 shield
4
No Connect
5
No Connect
6
DDC clock
7
DDC data
8
No Connect
9
T.M.D.S. data1-
10
T.M.D.S. data1+
11
T.M.D.S. data1 shield
12
No Connect
13
No Connect
14
+5V Power
15
Ground (for +5V) - Cable detect
16
Hot plug detect
17
T.M.D.S. data0-
18
T.M.D.S. data0+
19
T.M.D.S. data0 shield
20
No Connect
21
No Connect
22
T.M.D.S clock shield
23
T.M.D.S. clock+
24
T.M.D.S. clock-
Environmental conditions
Operating
-Temperature C
: 0°c to 35°c
-Humidity
: 80 % max
-Altitude
: 0-3658m
-Air pressure
: 600-1100mBAR
Storage
-Temperature C
: -20 to 60°
-Humidity
: 85% max ( < 40
-Altitude
: 0-12192m
-Air pressure
: 300-1100mBAR
Note: recommend at 5°c to 35°C, Humidity less than 60 %