Re-programming Digital DDC IC
Step 1: After initialize alignment box, connecting all
cables and box as shown in Fig. 27(Unplug the 15th pin of
The DVI cable connecting with monitor).
Monitor A
2
2=D-sub connector
D-sub cable
Unplug the 15th pin of DVI cable connecting with monitor
Step 2: Read DDC data from monitor
1.
Click
icon as shown in Fig. 11 from the tool bar to bring up
the Channels "Configuration Setup" windows as shown in Fig. 28.
Click this button
2. Select the DDC2Bi as the communication channel.
As shown in Fig. 29.
DDC Instructions
PC
Monitor B(200PW8)
1=DVI-D connector
DC Power
~
8 12V
3
D-sub to DVI-D cable
To
Monitor
Printer
Port
Fig. 29
3. Click OK button to confirm your selection.
4. Click
icon (Read EDID function) to read DDC EDID data from
monitor. The EDID codes will display on screen as shown in Fig. 30.
1
Step 3: Modify DDC data (verify EDID version, week,
year)
Click
(new function) icon from the tool bar, bring up
Step 1 of 9 as shown in Fig. 31 .
EDID46 DDC application provides the function selection and
text change (select & fill out) from Step 1 to Step 9.
Fig. 27
Select and fill out,
If necessary.
Fig. 28
HUDSON 8
21
Fig. 30
Fig. 31