Sharp AL-2051 Service Manual page 111

Digital multifunctional system
Hide thumbs Also See for AL-2051:
Table of Contents

Advertisement

Main
Sub
Details of trouble
code
code
L3
00
Content Scanner return trouble
Detail
When the mirror base is returned for the
specified time (6 sec) in mirror initializing
after turning on the power, the mirror home
position sensor (MHPS) does not turn ON.
Or when the mirror base is returned for the
specified time (about 6 sec) after start of
copy return, the mirror home position sensor
(MHPS) does not turn ON.
Cause
Mirror unit abnormality
Scanner wire disconnection
Origin detection sensor abnormality
Mirror motor harness abnormality
Check
Use SIM 1-1 to check the mirror
and
reciprocating operations.
remedy
When the mirror does not return.
Check for disconnection of the scanner wire.
Check the harness and the connector
between the mirror motor and the MCU
PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home
position sensor.
L4
01
Content Main motor lock detection
Detail
When the main motor encoder pulse is not
detected for 100 msec.
Cause
Main motor unit abnormality
Improper connection or disconnection the
main motor and the harness.
MCU PWB abnormality
Check
Use SIM 25-01 to check the main motor
and
operations.
remedy
Check connection of the main motor
harness/connector.
Replace the main motor.
Replace the MCU PWB.
32
Content Exhaust fan motor lock detection trouble
Detail
The error detection is started after 2 sec
from starting rotation of the exhaust fan
motor.
1) The continuous rotation state of 250ms is
not detected for 1 sec after starting
detection.
2) When the lock sensor (in the exhaust fan)
detects the HIGH level (unstable) after
detection the lock state (stable state).
Cause
Exhaust fan motor connector connection
trouble
Exhaust fan motor trouble
MCU PWB trouble
Check
Exhaust fan motor connector connection
and
check
remedy
Exhaust fan motor replacement
Replace the MCU PWB.
Main
code
AL-2051 SIMULATION, TROUBLE CODES 10 - 35
Sub
Details of trouble
code
L6
10
Content Polygon motor lock detection
Detail
The lock signal (specified rpm signal) does
not return within a certain time (about 20
sec) from starting the polygon motor
rotation.
Cause
Polygon motor unit abnormality
Improper connection or disconnection of the
polygon motor and the harness.
MCU PWB abnormality
Check
Use SIM 61-1 to check the polygon motor
and
operations.
remedy
Check connection of the polygon motor
harness/connector.
Replace the polygon motor.
Replace the MCU PWB.
U1
03
Content Network board battery error
Details The RTC backup battery voltage on network
PWB falls.
Cause
The RTC backup battery voltage on network
PWB falls.
Check
Check voltage of the RTC back up battery.
and
Replace the battery.
remedy
U2
04
Content EEPROM read/write error (Serial
communication error)
Detail
EEPROM access process error
Cause
EEPROM abnormality
Check
Check that the EEPROM is properly set.
and
Use SIM 16 to cancel the trouble.
remedy
Replace the MCU PWB.
11
Content Counter check sum error (EEPROM)
Detail
Check sum error of the counter area in the
EEPROM
Cause
EEPROM abnormality
Check
Check that the EEPROM is properly set.
and
Use SIM 16 to cancel the trouble.
remedy
Replace the MCU PWB.
U9
99
Content Panel language error
Detail
Improper language data
Cause
A improper language data was downloaded.
Check
Update LCD data.
and
remedy

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents