Installation Instructions; Installing Your Air Conditioner; Electrical Requirements; Grounding Instructions - Amana P1212701R Service

Table of Contents

Advertisement

Installation Instructions

Installing Your Air Conditioner

NOTE: These instructions describe installation in a
typical wood framed window with a wood SLIDE-
BY sash, or installation in a metal CASEMENT
window. Modification may be necessary when
installing in windows constructed differently than
those illustrated herein.
High window accessory kit is available for window
heights up to 62" (1575mm).

Electrical Requirements

!
To avoid risk of electrical shock, personal injury, or
death follow the following.
• Electrical ground is required on this appliance.
• DO NOT ground to a gas line.
• If cold water pipe is interrupted by plastic, non-
metallic gaskets, or other insulating materials, DO
NOT use for grounding.
• Check with a qualified electrician if you are in doubt
as to whether the appliance is properly grounded.
• DO NOT modify the power supply cord plug. If it
does not fit the outlet, have a proper outlet installed
by a qualified electrician.
• DO NOT have a fuse in the neutral or grounding
circuit. A fuse in the neutral, or grounding circuit
could result in an electrical shock.
• DO NOT use an extension cord with this appliance.
Observe all local codes and ordinances.
RS4110001 Rev. 0
WARNING

Grounding Instructions

NOTE: Do not under any circumstances cut or remove
grounding prong from the plug or bend power
prongs to fit receptacle other than one for the
equipment. Such abuse of the plug can result in
electrical shock or overheating.
For your personal safety, this appliance must be
grounded. This air conditioner includes a power supply
cord with a three-prong grounding plug. To minimize
possible electrical shock hazard, the cord must be
plugged into a mating three-prong grounding wall
receptacle; and grounded in accordance with the
National Electrical Code (ANSI/NFPA 70-latest version)
and all local codes and ordinances. If a mating
three-prong grounding-type wall receptacle is not
available, it is the responsibility of the consumer to have
a properly grounded three-prong wall receptacle installed
by a qualified electrician.
If codes permit, and a separate grounding wire is used; it
is recommended that a qualified electrician determine
that the grounding path is adequate and not interrupted
by plastic, non-metallic gaskets, or other insulating
materials.
Do not use an extension cord. If product power cord is
too short, have a qualified electrician install an
appropriate receptacle.
Receptacle Wiring
Receptacle wiring should be a minimum of 14 gauge.
Use copper wire only. It is the responsibility of the
consumer to provide proper and adequate receptacle
wiring, installed by a qualified electrician.

Electrical Connection

Electrical ground is required on this appliance.
Electrical Requirements
A 115 volt (103.5 minimum, 126.5 maximum), 60 Hertz,
AC only, 15 ampere fused electrical supply is required. A
time delay fuse or time delay circuit breaker is also
required. A separate circuit, serving only this appliance,
MUST be provided.