Alarms; Technical Specifications; Standard Features - KitchenAid KRAB 6010 Instructions For Use Manual

Shock freezer
Table of Contents

Advertisement

501971102025_GB:Layout 1

Alarms

Alarm AL1
Alarm AS1
Alarm AS2
d-c alarm
Compressor not working
Fans not turning
The circuit board does not turn
on
The compressor is working but
the chamber is not cold

Technical specifications

Yield of blast chilling cycle
Yield of shock freezing cycle
Total number of wire shelves
Total power
Input
Power cable
Compressor power
Cooling gas type - quantity
Climatic class
Net weight

Standard features

2 stainless steel wire shelves (444x340x7 mm)
1 core probe
Left-hinged door
14-01-2008
16:29
Pagina 22
Operating data lost due to fault in the
mains power supply.
Faulty air temperature gauge
Faulty core probe
Top panel closed during cycle
1-Clixon tripped because of an overload.
2-No power
3-Safety pressure switch tripped
1-No power
2-Fan faulty
3-Condenser faulty
1-No power
2-Protection fuse broken
1-No cooling gas
2-Air condenser dirty
230 V-1-50Hz
900 W
3,9 A
22
Switch power off. Switch back on.
Replace the temperature gauge
Replace the probe
Open the top panel
1-Call a service technician
2-Check that the equipment is connected to
the power line
3-Call a service technician
1-Check connection to mains power supply
2-Call a service technician to replace the fan
3-Call a service technician to replace the
condenser
1-Check connection to mains power supply
2-Call a service technician to replace the
board
1-Call a service technician
2-Clean the condenser
Voltage
230 V-1-60Hz
7 kg
4 kg
n°3
1000 W
4,6 A
1.5m long with 16A shuko plug
410 (0,5) W (Hp)
R404A - 850gr
N
45 kg
115 V-1-60Hz
1000 W
8,8 A

Advertisement

Table of Contents
loading

Table of Contents