Download Print this page

Graco M73380 Instructions-Parts List Manual page 3

1200 series; 2000 series turbine sprayers

Advertisement

EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
INSTRUCTIONS
D This equipment is for professional use only.
D Read all instruction manuals, tags, and labels before operating the equipment.
D Use the equipment only for its intended purpose. If you are not sure, call your distributor.
D Do not alter or modify this equipment.
D Check equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure of the lowest rated system component. The Series
1200 and 2000 turbines have a working pressure of 6 psi (0.41 bar).
D Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Speci-
fications on page 5 for this information.
D Do not use hoses to pull equipment.
D Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose
Graco hoses to temperatures above 82_C (180_F) or below –40_C (–40_F).
D Wear hearing protection when operating this equipment.
D Do not lift pressurized equipment.
D Comply with all applicable local, state, and national fire, electrical, and safety regulations.
D Do not point the gun at anyone or at any part of the body.
D Do not put your hand or fingers over the gun fluid nozzle.
D Do not stop or deflect leaks with your hand, body, glove or rag.
D Do not "blow back" fluid; this is not an air spray system.
D Follow the Pressure Relief Procedure on page 9 if the fluid nozzle clogs and before cleaning,
checking or servicing the equipment.
D Tighten all fluid connections before operating the equipment.
D Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
WARNING
308423 3

Advertisement

loading

This manual is also suitable for:

M73428M73378M73432