b. Removal – With the set screw loose, pull the sunshield forward until it is
free of the sunshield bracket.
c. Optional – The bracket that holds the sunshield can also be removed if
desired. To remove the sunshield bracket, loosen and remove the
two (2) 3 mm countersunk screws using the supplied 3 mm Allen wrench.
The bracket can then be removed. Though it is not required for the
integrity of the Sentinel unit, it is recommended to re-insert and tighten
the two (2) 3 mm countersunk screws back into the Sentinel casing for
future use.

13 PC Configuration of IQeye Sentinel

NOTE: The default user name for all IQeye devices is "root" and the default password is "system".
IQeye cameras are configured for DHCP and will have an IP address assigned if a
DHCP server is on the network. If a DHCP server is not available, the camera IP
address will need to be configured using either IQfinder or IQmanager.
1. Download and install IQfinder from the Vicon website (www.vicon-security.
com). Launch IQfinder and scan for cameras on the network by clicking the
refresh button. The detected cameras will be displayed in the IQfinder
window (Figure 12). Select a camera from the list and click "Assign IP" to edit
the selected camera's network settings.
2. The "Assign IP" window allows the IP Address, Subnet, and Gateway of
the camera to be changed and alternatively the camera to be configured
for DHCP operation. Click the "Apply" button after making the desired
changes (Figure 13).
NOTE: Changing between a static IP address and DHCP will cause the camera to reboot.