Technical Data - Kemppi Master 2200 Operation Instructions Manual

Hide thumbs Also See for Master 2200:
Table of Contents

Advertisement

8. TECHNICAL DATA

MASTER 2200
Mains voltage
Rated power
Connection cable/fuses
Welding current range MMA
Electrode sizes to be welded
Welding current control
Open circuit voltage
Efficiency
Power factor
Open circuit power
Storage temperature range
Operation temperature range
Temperature class
Degree of protection
External dimensions:
Weight
Suitable accessories:
The product meets conformity requirements for CE marking.
10 – MASTER 2200/0530
3~, 50/60 Hz
380 V -10 % ... 415 V +6 %
25 % ED
220 A / 8,4 kVA
60 % ED
145 A / 5,5 kVA
100 % ED
110 A / 3,5 kVA
4 x 1,5S / 10 A delayed
15 A / 20,5 V ... 220 A / 28,8 V
ø 1,5 ... 4,0 (5,0) mm
stepless
80 V
82 % (220 A / 28,8 V)
0,9 (220 A / 28,8 V)
approx. 10 W
-40 ... +60°C
-20 ... +40°C
H (180°C) / B (130°C)
IP 23C
length
472 mm
width
152 mm
height
302 mm
12,5 kg
remote control units C 100C, C 100D
© KEMPPI OY

Hide quick links:

Advertisement

Table of Contents
loading