Sign In
Upload
Manuals
Brands
Honeywell Manuals
Security System
ADEMCO VISTA-40
Honeywell ADEMCO VISTA-40 Manuals
Manuals and User Guides for Honeywell ADEMCO VISTA-40. We have
3
Honeywell ADEMCO VISTA-40 manuals available for free PDF download: Installation And Setup Manual, User Manual, Programming Manual
Honeywell ADEMCO VISTA-40 Installation And Setup Manual (96 pages)
2-Partitioned security system
Brand:
Honeywell
| Category:
Security System
| Size: 0.71 MB
Table of Contents
Table of Contents
3
List of Figures
5
Conventions Used in this Manual
6
SECTION 1: General Description
7
About the VISTA-40
7
Features
7
Event Log
8
SECTION 2: Partitioning
9
Theory of Partitioning
9
Setting-Up a Partitioned System
9
SECTION 3: Installing the Control
11
Mounting the Control Cabinet
11
Installing the Cabinet Lock
11
Grade a Mercantile Premises Listing Guidelines
11
Figure 3-1: Installing the Lock
11
Grade a Mercantile Safe and Vault Listing Guidelines
12
Installing the Control's Circuit Board
12
Figure 3-2: Cabinet Attack Resistance Considerations
12
Figure 3-3: Mounting the PC Board
12
Installing the Keypads
13
Figure 3-4: Keypad Connections to Control Panel
13
Figure 3-5: Using a Supplementary Power Supply
13
Installing External Sounders
14
Figure 3-6: Wiring Polarized Fire Devices
14
Telephone Line Connections
15
Figure 3-7: Wiring Nonpolarized Burglary Devices
15
Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9
16
Figure 3-8: Telephone Line Connections
16
Figure 3-9: Wiring Connections for Zones 1-9
16
Figure 3-10: 2-Wire Smoke Detector on Zone 1
17
Figure 3-11: 4-Wire Smoke Detectors
18
Figure 3-12: Wiring a 333PRM to the Control
18
Figure 3-13: Wiring a 333PRM Using a 4204
19
Figure 3-14: Wiring a 333PRM Using a 4204 and a Power Supply
19
Installing RPM Devices
20
Figure 3-15: Wiring Latching Glassbreaks to Zone 8
20
Figure 3-16: Polling Loop Connections to the VISTA-40
21
Figure 3-17: Polling Loop Connections Using One 4297 Extender Module
22
Figure 3-18: Polling Loop Connections Using Multiple Extender Modules
22
Wireless Zone Expansion
23
Figure 3-19: Installing the 5881ENHC with Tamper Protection
23
Figure 3-20: 5881 RF Receiver (Cover Removed)
24
Installing Relay Devices
26
Installing the Ground Start Module
27
Figure 3-21: 4204 Relay Module
27
Figure 3-22: 4204CF Relay Module
27
Installing a Remote Keyswitch
28
Figure 3-23: Ground Start Module Connections
28
Remote Keypad Sounder
29
Long Range Radio Connected to the J7 Triggers
29
Installing a 4100SM
29
Figure 3-24: Remote Keyswitch Wiring
29
Figure 3-25: Remote Keypad Sounder Wiring
29
Installing the 4285/4286 VIP Module
30
Figure 3-26: 4100SM Using a Serial Printer
30
Figure 3-27: VIP Module Connections
31
Installing the Audio Alarm Verification Module
32
Connecting the Transformer
33
Figure 3-28: UVS Connections to the Control Panel
33
Figure 3-29: 1361 Transformer and Battery Connections
34
Figure 3-30: 1361X10 Transformer Connections
34
Panel Earth Ground Connections
35
Determining the Control's Power Supply Load
35
Determining the Size of the Standby Battery
36
SECTION 4: Programming
39
Program Modes
39
Entering and Exiting Programming Mode
39
Data Field Programming Mode
39
#93 Menu Mode Programming
40
Programming Partition-Specific Data Fields
40
Programming System-Wide Data Fields
40
Index
41
Zone Number Designations
42
Zone Response Type Definitions
43
Zone Input Type Definitions
44
Programming for 4100SM
45
Programming for Access Control
45
SECTION 5: Data Field Descriptions
47
About Data Field Programming
47
Programming Data Fields
47
Primary Phone Number
50
Secondary Phone Number
50
Download Phone Number
50
Download ID Number
50
Download Command Enables
50
Prevent Zone XX Bypass
50
Normally Closed or Eolr (Zones)
50
Dial Tone Pause
50
Dial Tone Detection
51
Ring Detection Count
51
Low Speed Format (Secondary)
51
Sescoa/Radionics Select
51
First Test Report Time
54
Restore Report Timing
54
Rf Transmitter Check-In Interval
55
Touchtone with Rotary Backup
55
Wireless Keypad Tamper Detect
56
Wireless Keypad Assignment
56
Disable Download Callback
57
Zone 5 Audio Alarm Verification
57
Event Log Types
57
Relay Timeout XXX Minutes
57
Relay Timeout Yyy Seconds
57
Number of Partitions
57
Number of Codes Per Partition
58
Enable Goto for this Partition
58
Use Partition Descriptor
58
Enable J7 Triggers for Partition
58
Supervision Pulses for Lrr
58
SECTION 6: Downloading Primer
59
General Information
59
Getting On-Line with a Control Panel
60
On-Line Control Functions
60
Direct-Wire Downloading
61
Telco Handoff
61
Figure 6-1: Direct-Wire Downloading Connections
61
SECTION 7: Setting the Real-Time Clock
63
General Information
63
Setting the Time and Date
63
SECTION 8: User Access Codes
65
General Information
65
User Codes & Levels of Authority
65
Multiple Partition Access
66
Adding a Master, Manager, or Operator Code
67
Changing a Master, Manager, or Operator Code
68
Adding an RF Key to an Existing User
68
Deleting a Master, Manager, or Operator Code
68
Exiting the User Edit Mode
68
SECTION 9: Testing the System
69
Battery Test
69
Dialer Test
69
Burglary Walk-Test (Code + [5] TEST)
69
Armed Burglary System Test
69
Testing Wireless Transmitters
70
Transmitter ID Sniffer Mode
70
Trouble Conditions
71
To the Installer
71
APPENDIX A: Regulatory Agency Statements
73
UL Installation Requirements
73
UL609 Grade a Local Mercantile Premises/Local Mercantile Safe & Vault
73
UL365 Police Station Connected Burglar Alarm
73
UL611/UL1610 Central Station Burglary Alarm
74
California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements
74
APPENDIX B: Summary of System Commands
77
APPENDIX C: Specifications
79
APPENDIX D: Contact ID Event Codes
81
Table of Contact ID Event Codes
81
Index
83
Table of Contents
84
The Limitations of this Alarm System
87
Limited Warranty
88
Advertisement
Honeywell ADEMCO VISTA-40 User Manual (56 pages)
2-Partiotioned Security system
Brand:
Honeywell
| Category:
Security System
| Size: 0.31 MB
Table of Contents
Table of Contents
3
System Overview
5
General
5
A Partitioned System
5
Zones
5
Fire Protection
6
Burglary Protection
6
Alarms
6
Memory of Alarm
7
To Access Another Partition (GOTO Command)
7
Self-Help Feature
7
Phone Access & Voice Response Capability
8
About the Keypads
9
General
9
The Alpha Keypad
9
Functions of the Keypad
10
Entry/Exit Delays
13
General Information
13
Security Codes & Authority Levels
14
General Information
14
Duress Code
14
Quick Arming
14
Authority Levels
15
General Rules on Authority Levels and Changes
16
To Exit User Edit Mode
16
To Add a User
17
To Change a User's Code
18
To Delete a User
19
Accessing Other Partitions
20
To Access Another Partition
20
Global Arming
20
Checking for Open Zones
22
Using the ✳ READY Key
22
Displaying All Zone Descriptors
23
Using the ✳ READY Key
23
Bypassing Protection Zones
24
Using the 6 BYPASS Key
24
Quick Bypass
25
Displaying Bypassed Zones
25
Arming Perimeter Only
26
Using the 3 STAY Key
26
Arming Perimeter Only
27
Using the 7 INSTANT Key
27
Arming All Protection
28
Using the 2 AWAY Key
28
Arming All Protection
29
Using the 4 MAXIMUM Key
29
Disarming and Silencing Alarms
30
Using the 1 off Key
30
Memory of Alarm
30
Using the Keyswitch
31
General
31
Arming
31
Disarming
31
Chime Mode
32
Using the 9 Key
32
Viewing Alarm Company Messages
33
General Information
33
Panic Keys
34
Using Panic Keys
34
Access Door Control
35
General Information
35
Executing
35
Using #70 Relay Menu Mode
36
General Information
36
Event Log Procedures
37
General Information
37
To Display the Event Log
37
Testing the System
39
(To be Conducted Weekly)
39
Using the 5 TEST Key
39
Testing Your System
39
Fire Alarm System
40
In Case of Fire Alarm
40
Silencing a Fire Alarm
40
Typical Trouble Displays
41
Power Failure
42
Recommendations for Smoke and Heat Detectors
43
Recommendations for Proper Intrusion Protection
44
Emergency Evacuation
45
Maintaining Your System
46
Taking Care of Your System
46
Replacing Batteries in Wireless Sensors
46
Silencing Low Battery Warning Tones at the Keypad
47
Routine Care
47
Quick Guide to System Functions
48
Summary of Audible Notification
49
Index
54
Honeywell ADEMCO VISTA-40 Programming Manual (36 pages)
2-Partitioned security system
Brand:
Honeywell
| Category:
Security System
| Size: 0.34 MB
Table of Contents
Table of Contents
2
Recommended Programming Procedure
3
Program Field Index
4
VISTA-40 Programming Form
5
Partition-Specific Fields
9
Programming with #93 Menu Mode
10
Zone Programming
11
5800 Series Transmitters Loop Designations
13
Expert Mode Zone Programming
14
Alpha Descriptors Programming
17
Alpha Descriptor Vocabulary
20
Device Programming
21
Relay Programming
22
Relay Voice Descriptors
25
Relay Voice Descriptors and Custom Word Substitutes Vocabulary
26
Custom Word Substitutes for VIP Module Annunciation
26
System Layout Worksheets
27
Relay Outputs Worksheets
33
VISTA-40 Summary of Connections Diagram
35
Advertisement
Advertisement
Related Products
Honeywell ADEMCO VISTA-48A
Honeywell ADEMCO VISTA-48E
Honeywell Ademco Vista-48 series
Honeywell Ademco Vista-48LA
Honeywell ADEMCO VISTA-48D
Honeywell Ademco VISTA-50P
Honeywell ADEMCO VISTA-120
Honeywell VISTA-15P
Honeywell VISTA-20PS Series
Honeywell VISTA-128BPEN
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL