Principle method of operation

The principle method of operation is based on the vapour compression cycle with any additional heat being provided by
the built in electric heater. The control unit controls the heat pump using the outdoor sensor T2 and the fl ow sensor T1
according to the set heat curve. If the heat pump is unable to meet the heating requirements, the HWDU and the additional
electric heater starts automatically and together with the heat pump provides the required temperature. Hot water is priori-
tised and controlled by a sensor, T3 in the hot water cylinder. While the DHW is being heated in the hot water cylinder, the
CH production by the heat pump is stopped temporarily through a three-way valve. When the DHW temperature is satisfi ed
the heat pump continues the CH production.
Operation in extreme cold conditions:
At outdoor temperatures lower than approximately -20, the compressor in the heat pump is switched off and all heating and
hot water heating is via the built in electric heater.
Greensource heat pump and HWDU
* The drawing above shows the correct connection method for the heat pump where the fl ow rate around the heating system can fall below 70% of the
nominal fl ow (i.e. system with zone controls and thermostatic radiator valves). If the heating system has been designed to be fully open at all times then the use
of the primary water storage tank is not required
19
Connecting to the heating system
E10
Radiator system
C11
Expansion vessel
C12
Primary water storage tank*
G1A
Radiator pump
G1B
Radiator pump
P11
Pressure gauge
Q10
Mixing valve
Q12
Isolating valve
Q13
Water outlet
E20
Heating system
E21
Heat pump
F21
Safety valve
G2
Heating system pump
G3
Fan
Q20
3-way valve
Q21
3-way valve
Q22
Air vent
V21
Filter heating system
E40
Tap water system
C41
Expansion vessel
E41
Hot water cylinder
V40
Hot water
W40
Cold water
F42
Temperature & pressure
relief valve
Q42
Isolation valve
Q43
Pressure reducing valve
Q44
Non return valve
Q45
Tundish
Sensors
T1
Heating system fl ow
sensor (indoor unit)
T2
Outdoor sensor
T3
DHW sensor
T5
Room sensor
T6
Hot gas sensor
T8
Heat pump fl ow sensor
(outdoor unit)
T9
Heat pump return sensor
(indoor unit)
T10
Condenser
T11
Evaporator temp.
T12
Air intake