Terminal Diagram Greensource Heat Pump - Hwdu - Worcester GREENSOURCE 6 kW Installation Manual

Heat pump with hot water distribution unit
Hide thumbs Also See for GREENSOURCE 6 kW:
Table of Contents

Advertisement

Wiring diagram

Terminal diagram Greensource heat pump - HWDU

Isolation switch, not included.
Fusing:
Greensource 6 kW: 16A
Greensource 7 kW: 25A
Greensource 9.5 kW: 25A
HWDU: 25A
HWDU
Measurement transformers
on the incoming supply to
the house fuse box.
G2: To protect the heat carrier pump G2 during stand alone operation of
HWDU it is not connected from the factory. If the heat pump is to be
used
G2 is connected with the quick connector in
the distribution box.
T2: Outdoor sensor
T5: Room sensor
It is recommended that a separate residual current device is fi tted
to the heating system.
24
Heat pump

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensource 7 kwGreensource 9.5 kw

Table of Contents