Fit The Fi Lter Valve - Worcester GREENSOURCE 6 kW Installation Manual

Heat pump with hot water distribution unit
Hide thumbs Also See for GREENSOURCE 6 kW:
Table of Contents

Advertisement

Dimensions, clearance and plumbing connections
Pipe connections
The following connections are made to the HWDU:
A 32 mm plastic pipe is taken from the waste water pipe to the fl oor drain.
The fl ow is connected to the inlet marked For ward fl ow.
The return is connected to the inlet marked Return fl ow. Cold water and
hot water are connected to inlets marked Cold water and Hot water.
The following connections are made to the heat pump:
A 32 mm plastic pipe is drawn from the drainage pipe to the fl oor drain.
Pipe dimensions
Flow/return
Clamping ring connection
CW and HW
Clamping ring connection
To/from connections
Clamping ring connection
Clamping ring connection
Waste water/drainage
View connection area HWDU
seen from behind
2) To the heat pump.
(Connect to 2) in the heat pump picture.
Flow heating system
Fit the fi lter valve
The task of the particle fi lter is to fi lter out dirt before it can enter the
heat pump. Accordingly, the supplied fi lter valve should always be fi tted
on the return pipe on the hot side, between the HWDU and the outdoor
heat pump. It should be fi tted as close to the heat pump as possible and be
horizontal.
mm
ø22
mm
ø22
mm
ø22
(in the HWDU)
mm
ø28
(n the heat pump)
mm
ø32
(in both)
Return heating system
1) From the heat pump.
(Connect to 1) in the heat pump picture.
Hot water
HWDU top view
14
HWDU front view
Cold water