(10) Adjusting the scanner leading edge registration
Perform the following adjustment if there is regular error between the leading edges of
the copy image and original.
U034
U 402
(P.3-3-18)
(P.3-3-20)
Caution: Before making the following adjustment, ensure that the above adjustments
have been made in maintenance mode.
<Procedure>
Start
Enter maintenance mode.
Enter "066" using the numeric keys.
Press the print key.
Press the interrupt key.
Set an A3 size original and
make a test copy with
the 100% magnification.
Is the scanner
leading edge registration
correct?
Yes
Press the stop/clear key.
Exit maintenance mode.
End
U403
U066
(P.3-3-40)
Press the print key.
For copy sample 1, decrease
No
the value using the Down key.
For copy sample 2, increase
the value using the Up keys.
Setting range: –32.0 - +32.0
Changing the value by 1 moves
the leading edge by 0.17 mm.
Reference: 0
U071
(P.3-3-98)
Original
Copy
sample 1
Figure 3-3-47
The new setting
is stored.
2A3/4
U404
(P.3-3-100)
Copy
sample 2
3-3-39