Toshiba RAV-162BH-PE Service Manual page 58

Air-conditioner split built-in duct type, heat pump; split ceiling type, heat pump; split wall type, heat pump; split cassette type, heat pump
Table of Contents

Advertisement

NO.
ITEM
4
Fan speed control
4-1 [HIGH], [MED], [LOW] and [AUTO] are available.
4-2 [Ultra low] or [Stop] when compressor is turned off while heating is being
4-2
4-3 In the auto fan, the fan speed is changed by the difference between Ta and Ts,
4-2
5
Cold draft
preventing control
6
Freeze preventing
control
(Low temp. release)
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
OUTLINE OF SPECIFICATIONS
performed.
as shown below.
-Cooling-
When performing heating operation,
indoor fan control is carried out as
follows based on temperature detection
of Tc sensor.
C zone:
Depending upon fan
speed setting of the
remote controller
B zone:
Indoor fan at "L"
A zone:
Fan stop
When performing cooling operation, the
following control is done based on
temperature detection of Tc sensor.
When starting the operation, the point
P is made +3°C.
When [J] zone is detected,
timer counting starts.
When [K] zone is detected,
timer counting is discontinued
and held on.
When [I] zone is detected, timer is
cleareed for returning back to
ordinary operation.
When timer counting becomes full time, the ourdooor unit stops and the point P
is changed to +12°C to be covered by check display.
When [I] zone is reached, the temperature is returned back to +3°C.
-58-
www.heronhill.co.uk
[Stop] is cold draft
prevented by Tc.
-Heating-
-Auto-changeover-
Full Time
Fax: 01823 665807
REMARKS
MIN 7 min.