6.2
Outline of remote controller's functions
NO
KEY
SWITCH
[ON/OFF]
1
2
MODE
SELECT
3
4
+
5
TIME
ADJUST
+
TIME
ADJUST
6
CHECK
7
Reset
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
OUTLINE
OF
When this button is pushed once, the air conditioner is turned on,
with the operation lamp coming on.
If pushed once more, it will be turned off, the operation lamp going off.
If pushed for 5 sec. in the mode of turning on the air conditioner,
goes into test run mode.
Each time this button is pushed, the [MODE] setting is changed over
cyclically, [AUTO]
[COOL]
Þ
[FAN ONLY]
[AUTO].
Þ
If pushed continuously, the setting will be changed in one step
every 0.5 sec.
Each time this button is pushed, the [FAN] setting is changed over
cyclically, [AUTO]
[LOW]
Þ
If pushed continuously, the setting will be changed in one step
every 0.5 sec.
Each time [+] this button is pushed, the [TEMP] setting of
temperature is raised by 1
If [+] is pushed continuously, the setting will be raised by 1
every 0.5 sec.
Each time [
] button is pushed, the setting of temperature is lowered
by 1
°
C.
If [
] is pushed continuously, the setting will be lowered by 1
every 0.5 sec.
Each time [TIME ADJUST] button is pushed, the [TIME] display is
changed cyclically. The time can be changed while the TIME display
stays flashing.
(flashing)
[CLOCK]
[CLOCK]
Þ
[12:00]
[12:00]
While the TIME display stays flashing, the time gains one minute
upon each pressing of [+].
If [+] is pushed continuously, the time gains 10 minutes every 0.25 sec.
While the TIME display stays flashing, the time goes back one
minute upon each pressing of [
If [
] is pushed continuously the time goes back 10 minutes every
0.25 sec.
Each time the [TIMER SELECT] button is pushed, timer mode
changes over cyclically, [
[ON
OFF]
[ON
OFF]
Þ
Þ
If pushed continuously, the timer mode will be changed in one stop
every 0.5 sec.
Pressing this key for 0.5 sec. provides [MALFUNCTION CHECK],
indicating on liquid crystal the contents of inspection in the sequence
of (times of compressor-on)
(contents of malfunction for #2 unit)
Pressing this key for 5 sec. gives "Indoor microcomputer reset mode"
to reset the indoor microcomputer by way of hardware.
Pressing this key for 10 sec. gives "Check contents clear mode" to
clear the contents of inspection stored in the remote controller
provided, however, times of compressor-on is not cleared.
By pressing the reset key, the remote controller is reset by way of
hardware. (The setting/display are in initial values with the check
memory cleared.)
-47-
www.heronhill.co.uk
SPECIFICATION
[HEAT1]
[HEAT2]
Þ
Þ
Þ
[MED]
[HIGH]
[AUTO].
Þ
Þ
Þ
°
C.
°
C
(flashing)
(flashing)
[ON TIME]
[OFF TIME]
Þ
Þ
[6:00]
[18:00]
].
] (CONTINUE)
[ON]
[OFF]
Þ
Þ
[CYCLE]
[
].
Þ
Þ
(contents of malfunction for #1 unit)
Þ
.......
Þ
REMARKS
Fan speed
In the 18-29
°
Control range
°
C
If time is not set,
12:00
16:00
18:00
are set automatically.
Þ
The indication of the
indoor unit which has not
any malfunction content is
Þ
skipped.