4.14 RAV-162AH-PE
No.
PARTS NAME
1
Compressor
2
Outdoor unit fan motor
Running capacitor for
3
outdoor
fan motor
4
Magnetic contactor
5
High pressure switch
Soleniod coil for four-way
6
valve
7
Crankcase heater
8
Sensor for defrosting
9
Fuse
10 Sensor for cooling operation
in low ambient temperature
11 Soleniod coil for two-way
valve
12 Running capacitor for
compressor
13 Transformer
(Outdoor unit)
14 Overload relay
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
TYPE
PH250X3-4LS
SMF-230-39N-2 Output (Rated) 39W, 6 pole, 230V, 1 phase, 50Hz
EEP2G405HQ
FMca-1S
ACB-2TBO4W
CHV-AC240V
NEV AC 240V
MT-44MP456W
FT-67
OL-177GM15
-36-
www.heronhill.co.uk
SPECIFICATIONS
Output (Rated) 2.0 kW, 2 pole, 220/240V, 1 phase,
50Hz
AC 400V, 4 µF
AC 220-240V, 50Hz
Tripping pressure 30kg/cm²G
pressure 23kg/cm²G
AC 220-240V
AC 240V, 28W
Maximum input
15.5mA
5A
Maximum input
15.5mA
AC 220-240V, 50Hz
AC 440V 45µF
187-264V
AC 240V, Tripping temp: 165°C, Resetting temp: 80°C
Resetting
°C
–12
10
K
W
67.5
21.3
°C
–12
10
K
W
67.5
21.3