This is a copy of the labels that accompany each LRI6E Gas Insert. We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
FPI Fireplace Products International Ltd.,
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements.
AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut être utiliser pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été approuvé de nouveau par l'autorité compétente.
This vented gas fireplace heater is not for use with air filters.
For use only with barrier (Part # 299-100) Follow installation instructions.
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz, Less than 10A
VENTED GAS FIREPLACE HEATER -
GAZ À ÉVACUATION - NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
Listed: VENTED GAS FIREPLACE HEATER
/ FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
é
Certified to:
CAN/CGA-2.17-M91(R2009)
Tested
to ANSI Z21.88-20
:
4001172
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
5
Low Setting Man. pressure
1.6"
Max. Manifold pressure
3.5"
Orifice size
#3
Minimum input
2 ,000
Maximum input
3 ,000
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Maximum input
Minimum Clearances to Combustibles
from Insert
Side wall
A
12
(
305
mm)
Ceiling
B
60
(1524mm)
12"
Mantel
Max.
C
40
(
1016
mm)
Min. Alcove Width
K
5 "
6
(1
422
mm)
Max. Alcove Depth
L
36
(914mm)
Delta BC, CANADA
Duplicate Serial number
NE PAS ENLEVER CETTE ETIQUETTE
CANADA and U.S.A.
14 &
CSA 2.33-20
14
Serial No. / No de serie
MODEL L
RI6
E-NG
É
QUIP A L'UISINE POUR GAZ NATURAL
É
MODEL L
Pression d'allimentation minimum
WC
(1.25 kpa)
WC
(0.41 kpa)
Pression la tubulure d' chappement basse
WC
(0.87 kpa)
Pression la tubulure d' chappement lev e
2
DMS
Dimensions de l'orifice
5
Btu/h
( .
7 33
kW)
D bit Calorifique minimum
é
8
Btu/h
( .
11 14
kW)
D bit Calorifique maximum
é
MODEL L
RI6
E-LP
É
QUIP A L'UISINE POUR GAZ PROPANE
É
MODEL L
11"
WC
(2.73 kpa)
Pression d'allimentation minimum
6.4"
WC
(1.59 kpa)
Pression la tubulure d' chappement basse
10"
WC
(2.48 kpa)
Pression la tubulure d' chappement lev e
#5
1
DMS
Dimensions de l'orifice
30
,000
Btu/h ( .
8 79
kW)
D bit Calorifique minimum
é
3 ,000
8
Btu/h ( .
11 14
kW)
D bit Calorifique maximum
é
Mantel Clearances
*Min. Hearth Width
*
Min. Hearth Length
Max. Mantle Depth
A
G
@ 24" form fireplace opening
L
B
* See installation manual for hearth requirements.
C
*If unit is raised 6" from the floor - no hearth
required.
D
E
K
K
MADE IN CANADA /FABRIQUE AU CANADA
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour l'utilisation seulement avec la Partie de barrière No. (299-100)
Suivez les instructions d'installation.
Fan Part # 911-071
NOT FOR USE WITH SOLID FUELS. /
safety decal
436
DO NOT REMOVE THIS LABEL /
436
RI6
E-NG
é
à
é
é
é
à
RI6
E-LP
é
à
é
é
é
à
D
14
(356mm)
E
4
4
(1016mm)
G
12"
(305mm)
FOYER AU
91 - 9 383a
LRI6E / HRI6E Direct Vent Gas Insert
|
7
| 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lri6e-lpHri6e-ngHri6e-lpLri6eHri6e

Table of Contents