FOR YOUR SAFETY

This appliance requires air for proper combustion.
Always provide adequate combustion and
ventilation air. Follow instructions and information
in CAN/CGA B149 (in Canada) or the National Fuel
Gas Code ANSI Z223.1 (in the USA), regarding
requirements for combustion and ventilation air.

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit must
be disconnected.
Gas Input Capacity:
Natural Gas
38,000
Propane
38,000
Min. Input
(with Proflame GTMF remote)
Natural Gas
25,000
Propane
30,000
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to 4,500'
(0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 140 CFM.
Log Set: Ceramic fibre, 6 per set - LRI6E
Glass Crystals: 11 lbs of glass crystals - HRI6E
Vent System: 3" x 4" The efficiency rating of the
appliance is a product thermal efficiency rating
determined under continuous operating conditions
and was determined independent of any installed
system.
GAS PRESSURE
TESTING
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa).
INSTALLATION INTO A SOLID
FUEL BURNING FIREPLACE
OR FACTORY BUILT
FIREPLACE
Btu/h
The LRI6E / HRI6E Gas Inserts have been tested
and approved to be vented into any masonry
Btu/h
fireplace or approved solid fuel burning factory
built fireplace that will allow the insert to physically
fit into the firebox. Refer to "Minimum Fireplace
Dimensions" section for minimum fireplace
Btu/h
clearances.
Btu/h
If the factory built fireplace* height is too low for
your Insert, you may remove the smoke baffle
plate, damper, refractory (firebricks), glass doors,
screen rails, screen mesh and log grates from
the factory built fireplace as long as these items
are saved and are reinstalled in the event that the
Insert is removed.
Smoke shelves, shields and baffles may be removed
if attached by mechanical fasteners. If any part is
removed it must not weaken the structural integrity
of the factory built fireplace.
NOTE: Any alterations made to the listed solid fuel
burning factory built fireplace may void the listing
of the fireplace.
*Check with your local inspector before commencing
with this installation.
Installer must mechanically attach the supplied
label to the inside of the firebox of the fireplace into
which the gas fireplace insert is installed.
"WARNING: This fireplace has been converted
for use with a gas fireplace insert only and cannot
be used for burning wood or solid fuels unless
all original parts have been replaced, and the
fireplace re-approved by the authority having
jurisdiction."
installation
LRI6E / HRI6E Direct Vent Gas Insert
|
11