ELECTRONIC AIR CLEANER

Line voltage power can be supplied from the terminal la-
beled "EAC" and a line voltage neutral terminal on the con-
trol board. This will power the electronic air cleaner
whenever the circulating air blower is in operation.

HUMIDIFIER

Line voltage power is supplied from terminal labeled "HUM"
to a line voltage neutral terminal on the control board. This
will power the humidifier whenever the burner is on and the
circulating air blower is operating in the heating mode.
NOTE: Maximum current – 1.0 amps for each option (hu-
midifier or electronic air cleaner).
78
FILTERS
Keep filters clean at all times. A filter is not provided with
the furnace, but one must be field-supplied and in-
stalled.
It is recommended to replace the furnace filter periodically
to maintain optimum furnace performance.