NOTE: A heat loss calculation must be performed to prop-
erly determine the required furnace BTU size for the struc-
ture. Also, the duct must be properly designed and
installed for proper airflow. Existing ductwork must be in-
spected for proper size and to make sure that it is properly
sealed. Proper airflow is necessary for both user comfort
and equipment performance.
Before opening the furnace carton, verify that the data
tags on the carton specify the furnace model number
that was ordered from the distributor and are correct for
the installation. If not, return the unit without opening the
carton. If the model number is correct, open the carton
and verify that the furnace rating label specifies the
same furnace model number that is specified on the car-
ton label. If the model numbers do not match, return the
furnace to the distributor.
IMPORTANT: Proper application, installation and mainte-
nance of this furnace and system is a must if consumers are
to receive the full benefits for which they have paid.
FIGURE 1
FURNACE COMPONENTS
10
11
7
8
23
9
6
5
1
2
4
3
22

GENERAL INFORMATION

14
12
13
The (-)95P series furnaces are design-certified by CSA for
use with natural and propane gases as follows:
1. As non-direct vent central forced air furnaces taking
combustion air from the installation area or using air
ducted from the outside.
2. As direct vent central forced air furnaces with all com-
bustion air supplied directly to the furnace burners
through a special air intake system outlined in these in-
structions.Install this furnace in accordance with the
American National Standard Z223.1 – latest edition enti-
tled "National Fuel Gas Code" (NFPA54) and require-
ments or codes of the local utilities or other authorities
having jurisdiction. This is available from the following:
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
CSA-INTERNATIONAL
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
ITEM
NO.
DESCRIPTION
1
CONDENSATE TRAP
2
DOOR SWITCH
16
3
JUNCTION BOX
4
TRANSFORMER
5
WATER SENSOR (2)
15
6
MAIN PRESSURE SWITCH
7
EXHAUST TRANSITION
8
COUPLING (ELBOW TO TRANSITION)
17
9
EXHAUST
10
SHIPPING PLUG
11
FLAME SENSOR
12
OVER TEMPERATURE SWITCH
13
TOP PLATE
5
14
BURNER
15
IGNITER
16
COMBUSTION AIR INLET
17
GAS VALVE
18
INDUCED DRAFT BLOWER (IDB)
19
CAPACITOR
18
20
CONTROL MOUNTING PLATE
21
BLOWER
22
LOW VOLTAGE TERMINAL
21
23
COUPLING (IDB TO ELBOW)
24
FURNACE CONTROL
19
20
24
ST-A1194-02-XO
3