Horizontal Installations - Rheem R95P Installation Instructions Manual

(-)95p series
Table of Contents

Advertisement

DUCTING
FIGURE 9
AS - SHIPPED FLAT
ST-A1194-39-00
TABLE 1
NON-COMBUSTIBLE FLOOR BASES
Floor Base
No.
RXGC-B17
RXGC-B21
RXGC-B24

HORIZONTAL INSTALLATIONS

1. Position the unit to minimize long runs of duct or runs of
duct with many turns and elbows.
2. If summer air conditioning is desired, position the in-
door coil on the supply air side of the unit. Ensure that
no air can bypass this coil.
3. Connect the furnace to the supply air plenum.
4. Connect the return air ducting to the return air opening
at the return-air end of the unit. Make the connection air
tight to prevent the migration of toxic fumes and odors
including carbon monoxide from migrating into the liv-
ing space from an adjacent fuel-burning appliance.
NOTE: In horizontal configuration, side return air cut
out is not permitted.
44
INSTALLER BENT - UP
INSTALLER BENT - UP
ALTERNATE - BENT (DOWN)
Size
Cabinet
17
21
24
FIGURE 10
5. If a filter is installed near the furnace, be sure to
have adequate space for the unit filter.
NOTE: DO NOT take return air from bathrooms,
kitchens, furnace rooms, garages, utility or laundry
rooms, or cold areas.
FIGURE 11
NON-COMBUSTIBLE FLOOR BASE INSTALLATION INSTRUCTIONS
COMBUSTIBLE
COMBUSTIBLE
FLOOR
FLOOR
MATERIAL
MATERIAL
A
21 5/8"
FLOOR CUTOUT
FLOOR CUTOUT
DIMENSIONS
DIMENSIONS
FLOOR
BASE NO.
21 5/8"
RXGC-B17
RXGC-B21
RXGC-B24
CUT - OUT USING
EMBOSSED ANGLES AS
A GUIDE FOR PROPER
SIZE 23" x 14"
ST-A1194-04-X0
NON-COM-
NON-COMBUSTIBLE
FLOOR BASE
BUSTIBLE
FLOOR
BASE
CABINET
FLOOR CUTOUT
WIDTH
DIMENSION "A"
17.5"
17.0"
ST-A1194-43-00
20.0"
21.0"
23.5"
24.5"